NSN: 5925-01-146-1952

Circuit Breakers

CIRCUIT BREAKER

5925 - Circuit Breakers

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Thread Series Designator

    uns

  • Frequency In Hertz

    400.0 single location

  • Inclosure Protection Type For Which Designed

    moisture resistant and

  • Inclosure Protection Type For Which Designed

    hermetically sealed

  • Main Contact Tripping Mechanism Type

    trip free

  • Trip Release Characteristic

    time delay single location

  • Trip Release Method

    thermal single location

  • Circuit Protection Type

    overcurrent single location

  • Operating Voltage Type And Rating Per Pole In Volts

    28.0 dc single location

  • Operating Voltage Type And Rating Per Pole In Volts

    115.0 ac and

  • Maximum Continuous Load Current Rating Per Pole

    5.0 amperes dc single location

  • Thread Quantity Per Inch

    27

  • Iii Storage Type

    general purpose warehouse

  • Mounting Facility Type And Quantity

    1 threaded bushing

  • Iii End Item Identification

    4920-01-121-0603

  • Case Material

    plastic

  • Body Width

    0.570 inches nominal

  • Terminal Type And Quantity

    2 tab w/screw

  • Trip Release Ambient Temp Rating

    23.0 deg celsius nominal single location

  • Inclosure Protection Type For Which Designed

    shock resistant and

  • Inclosure Protection Type For Which Designed

    fungus resistant and

  • Trip Delay Time In Seconds Per Rated Continuous Current

    50.000 maximum at 200 pct single location

  • Trip Delay Time In Seconds Per Rated Continuous Current

    15.000 minimum at 200 pct and

  • Nominal Thread Size

    0.375 inches

  • Internal Trip Release Configuration

    series trip single location

  • Actuator Position Designation

    at pole one

  • Actuator Function

    trip-reset

  • Manual Actuator Type And Quantity

    1 push-pull

  • Reset Method

    manual

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    138.0 single location

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    50.0 dc single location

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    50.0 ac and

  • Maximum Continuous Load Current Rating Per Pole

    5.0 amperes ac and

  • Pole Quantity

    1

  • Mounting Surface To Terminal End Distance

    2.300 inches nominal

  • Center To Center Distance Between Terminals Parallel To Length

    0.790 inches nominal

  • Body Length

    1.140 inches nominal

  • Bushing Length

    0.250 inches nominal

  • Body Style

    1a single pole type

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...