Technical Characteristics
-
Operating Voltage Type And Rating Per Pole In Volts
102.0 dc third location
-
Center To Center Distance Between Terminals Parallel To Width
0.750 inches nominal
-
Special Handling Feature
magnetic
-
Pole Quantity
3
-
Internal Trip Release Configuration
relay trip second location
-
Thread Series Designator
unc
-
Actuator Position Designation
at each pole
-
Frequency In Hertz
50.0 second location or 60.0 second location
-
Reset Method
manual
-
Trip Release Duty Cycle
intermittent first location
-
Internal Trip Release Configuration
relay trip third location
-
Circuit Protection Type
overcurrent first location
-
Storage Type
general purpose warehouse
-
Actuator Function
trip-reset
-
Trip Delay Time In Seconds Per Rated Continuous Current
2.000 minimum at 200 pct first location and 20.000 maximum at 200 pct first location
-
External Actuator Linkage Arrangement
one, two, and three linked
-
Circuit Protection Type
overcurrent second location
-
Thread Quantity Per Inch
32
-
Internal Trip Release Configuration
series/relay trip first location
-
Arc Quenching Method
magnetic blowout
-
Body Length
2.500 inches nominal
-
Boss Height
0.140 inches nominal
-
Maximum Continuous Load Current Rating Per Pole
3.0 amperes dc third location
-
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
1000.0 ac first location
-
Trip Release Characteristic
instantaneous second location
-
Frequency In Hertz
50.0 first location or 60.0 first location
-
Auxiliary Trip Coil Voltage Type And Rating In Volts
120.0 ac nominal first location
-
Operating Voltage Type And Rating Per Pole In Volts
250.0 ac first location
-
Manual Actuator Type And Quantity
3 toggle
-
Body Width
2.200 inches minimum and 2.800 inches maximum
-
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
1000.0 ac second location
-
Case Material
plastic
-
Center To Center Distance Between Terminals Parallel To Length
1.938 inches nominal
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
2.062 inches nominal
-
Trip Release Characteristic
instantaneous third location
-
Terminal Type And Quantity
6 threaded stud
-
Fragility Factor
moderately rugged
-
Operating Voltage Type And Rating Per Pole In Volts
115.0 ac second location
-
Trip Release Method
magnetic-hydraulic all locations
-
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
1000.0 dc third location
-
Body Style
multipole-multiple actuator type
-
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0 all locations
-
Trip Release Characteristic
time delay first location
-
Mounting Surface To Terminal End Distance
2.409 inches minimum and 2.533 inches maximum
-
Inclosure Protection Type For Which Designed
fungus resistant and moisture resistant
-
Mounting Facility Type And Quantity
6 threaded hole
-
Circuit Protection Type
undervoltage third location
-
Unpackaged Unit Weight
9.500 ounces
-
Maximum Continuous Load Current Rating Per Pole
20.0 amperes ac first location
-
Nominal Thread Size
0.138 inches
-
Maximum Continuous Load Current Rating Per Pole
20.0 amperes ac second location
-
Main Contact Tripping Mechanism Type
trip free
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
0.750 inches nominal