NSN: 5925-01-152-1188

Circuit Breakers

CIRCUIT BREAKER

5925 - Circuit Breakers

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Center To Center Distance Between Terminals Parallel To Length

    3.515 inches minimum and 3.579 inches maximum

  • Boss Height

    0.209 inches minimum and 0.229 inches maximum

  • Thread Quantity Per Inch

    32

  • Trip Release Method

    magnetic-hydraulic all locations

  • Body Style

    multipole-multiple actuator type

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0 all locations

  • Mounting Surface To Terminal End Distance

    3.172 inches minimum and 3.296 inches maximum

  • Nominal Thread Size

    0.138 inches

  • Body Width

    3.046 inches minimum and 3.140 inches maximum

  • Body Length

    5.768 inches minimum and 5.832 inches maximum

  • Main Contact Tripping Mechanism Type

    trip free

  • Arc Quenching Method

    magnetic blowout

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    2.718 inches minimum and 2.782 inches maximum

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    5000.0 ac all locations

  • Frequency In Hertz

    50.0 all locations or 60.0 all locations

  • Operating Voltage Type And Rating Per Pole In Volts

    480.0 ac all locations

  • Center To Center Distance Between Terminals Parallel To Width

    0.994 inches minimum and 1.058 inches maximum

  • Mounting Slot Width

    0.164 inches nominal

  • Manual Actuator Type And Quantity

    3 toggle

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    0.994 inches minimum and 1.058 inches maximum

  • Trip Delay Time In Seconds Per Rated Continuous Current

    0.150 minimum at 200 pct all locations and 0.750 maximum at 200 pct all locations

  • Case Material

    plastic

  • Terminal Type And Quantity

    6 threaded stud

  • Fragility Factor

    moderately rugged

  • Pole Quantity

    3

  • Circuit Protection Type

    overcurrent all locations

  • Inclosure Protection Type For Which Designed

    dustproof

  • Thread Series Designator

    unc

  • Actuator Position Designation

    at each pole

  • Reset Method

    manual

  • Mounting Facility Type And Quantity

    6 threaded hole and 6 slot

  • Storage Type

    general purpose warehouse

  • Maximum Continuous Load Current Rating Per Pole

    100.0 amperes ac all locations

  • Trip Release Characteristic

    time delay all locations

  • Actuator Function

    trip-reset

  • External Actuator Linkage Arrangement

    one, two, and three linked

  • Internal Trip Release Configuration

    series trip all locations

Related Manufacturers

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.