NSN: 5925-01-153-7491

Circuit Breakers

CIRCUIT BREAKER

5925 - Circuit Breakers

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Body Width

    2.060 inches minimum and 2.070 inches maximum

  • Trip Delay Time In Seconds Per Rated Continuous Current

    3.000 minimum at 200 pct first location and 11.000 maximum at 200 pct first location

  • Maximum Continuous Load Current Rating Per Pole

    30.0 amperes ac third location

  • Circuit Protection Type

    overcurrent second location

  • Thread Quantity Per Inch

    32

  • Mounting Facility Type And Quantity

    8 threaded hole

  • Unpackaged Unit Weight

    12.500 ounces

  • Circuit Protection Type

    undervoltage fourth location

  • Trip Release Method

    magnetic-hydraulic all locations

  • Body Style

    multipole-multiple actuator type

  • Circuit Protection Type

    overcurrent third location

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0 all locations

  • Switch Voltage Rating And Type In Volts

    250.0 ac and 30.0 dc

  • Internal Trip Release Configuration

    series trip first location

  • Trip Release Characteristic

    time delay first location

  • Internal Trip Release Configuration

    relay trip fourth location

  • Fragility Factor

    moderately rugged

  • Switch Terminal Type

    tab, solder lug

  • Center To Center Distance Between Terminals Parallel To Width

    0.750 inches nominal

  • Special Handling Feature

    magnetic

  • Thread Series Designator

    unc

  • Actuator Position Designation

    at each pole

  • Frequency In Hertz

    50.0 second location or 60.0 second location

  • Reset Method

    manual

  • Auxiliary Switch Function And Quantity

    2 alarm

  • Frequency In Hertz

    50.0 third location or 60.0 third location

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    2000.0 dc fourth location

  • Operating Voltage Type And Rating Per Pole In Volts

    250.0 ac second location

  • Actuator Function

    trip-reset

  • Trip Delay Time In Seconds Per Rated Continuous Current

    3.000 minimum at 200 pct third location and 11.000 maximum at 200 pct third location

  • Storage Type

    general purpose warehouse

  • Circuit Protection Type

    overcurrent first location

  • Trip Release Characteristic

    time delay third location

  • Body Length

    2.500 inches nominal

  • Boss Height

    0.140 inches nominal

  • Trip Release Characteristic

    instantaneous fourth location

  • Trip Delay Time In Seconds Per Rated Continuous Current

    3.000 minimum at 200 pct second location and 11.000 maximum at 200 pct second location

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    1000.0 ac first location

  • Frequency In Hertz

    50.0 first location or 60.0 first location

  • Operating Voltage Type And Rating Per Pole In Volts

    250.0 ac first location

  • Switch Contact Arrangement

    double pole, double throw

  • Maximum Continuous Load Current Rating Per Pole

    30.0 amperes ac first location

  • Maximum Continuous Load Current Rating Per Pole

    30.0 amperes ac second location

  • Manual Actuator Type And Quantity

    4 toggle

  • Operating Voltage Type And Rating Per Pole In Volts

    102.0 dc fourth location

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    1000.0 ac second location

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    1000.0 ac third location

  • Case Material

    plastic

  • Center To Center Distance Between Terminals Parallel To Length

    1.938 inches nominal

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    2.062 inches nominal

  • Pole Quantity

    4

  • External Actuator Linkage Arrangement

    one, two, three, and four linked

  • Mounting Surface To Terminal End Distance

    2.409 inches minimum and 2.533 inches maximum

  • Switch Location And Position Designation

    internal at pole two and internal at pole three

  • Inclosure Protection Type For Which Designed

    fungus resistant and moisture resistant

  • Terminal Type And Quantity

    8 threaded stud

  • Internal Trip Release Configuration

    series trip second location

  • Operating Voltage Type And Rating Per Pole In Volts

    250.0 ac third location

  • Nominal Thread Size

    0.138 inches

  • Trip Release Characteristic

    time delay second location

  • Switch Current Rating And Type In Amps

    10.0 ac and 4.0 dc

  • Internal Trip Release Configuration

    series trip third location

  • Main Contact Tripping Mechanism Type

    trip free

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    0.750 inches nominal

  • Arc Quenching Method

    magnetic blowout

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...