NSN: 5925-01-156-4426

Circuit Breakers

CIRCUIT BREAKER

5925 - Circuit Breakers

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    1.026 inches nominal

  • Trip Release Method

    magnetic-hydraulic all locations

  • Body Style

    multipole-multiple actuator type

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0 all locations

  • Switch Contact Arrangement

    single pole, double throw

  • Inclosure Protection Type For Which Designed

    fungus resistant and moisture resistant

  • Mounting Facility Type And Quantity

    6 threaded hole

  • Nominal Thread Size

    0.138 inches

  • Ultimate Trip Time Per Pole In Seconds

    800.000 maximum all locations

  • Switch Location And Position Designation

    external at pole one

  • Special Features

    anti-flashover barrier between poles

  • Main Contact Tripping Mechanism Type

    trip free

  • Center To Center Distance Between Terminals Parallel To Length

    3.550 inches nominal

  • Mounting Surface To Terminal End Distance

    3.550 inches nominal

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    5000.0 ac all locations

  • Frequency In Hertz

    50.0 all locations or 60.0 all locations

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    2.750 inches nominal

  • Boss Height

    0.220 inches nominal

  • ~1

    locations and 18.000 maximum at 400 pct all locat

  • Trip Delay Time In Seconds Per Rated Continuous Current

    800.000 maximum at 125 pct all locations and 20.000 minimum at 200 pct all locations and 130.000 maximum at 200 pct all locations and 4.000 minimum at 400 pct all locations and 70.000 minimum at 125 pct all locations and 0.012 minimum at 1000 pct all

  • Operating Voltage Type And Rating Per Pole In Volts

    277.0 ac all locations and 480.0 ac all locations

  • Manual Actuator Type And Quantity

    3 toggle

  • Body Width

    3.108 inches maximum

  • Auxiliary Switch Function And Quantity

    1 control

  • Case Material

    plastic

  • Terminal Type And Quantity

    6 threaded stud

  • Actuator Function

    reset

  • Switch Terminal Type

    tab, solder lug

  • Pole Quantity

    3

  • Circuit Protection Type

    overcurrent all locations

  • Switch Voltage Rating And Type In Volts

    250.0 ac

  • Thread Series Designator

    unc

  • Actuator Position Designation

    at each pole

  • Reset Method

    manual

  • Center To Center Distance Between Terminals Parallel To Width

    1.026 inches nominal

  • Switch Current Rating And Type In Amps

    10.0 ac

  • Trip Release Characteristic

    time delay all locations

  • External Actuator Linkage Arrangement

    one, two, and three linked

  • Internal Trip Release Configuration

    series trip all locations

  • Maximum Continuous Load Current Rating Per Pole

    20.0 amperes ac all locations

  • Body Length

    5.125 inches nominal

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...