NSN: 5925-01-156-7721

Circuit Breakers

CIRCUIT BREAKER

5925 - Circuit Breakers

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Fragility Factor

    moderately rugged

  • Switch Terminal Type

    tab, solder lug

  • Circuit Protection Type

    overcurrent all locations

  • Pole Quantity

    2

  • Thread Series Designator

    unc

  • Actuator Position Designation

    at each pole

  • Reset Method

    manual

  • Maximum Continuous Load Current Rating Per Pole

    100.0 amperes dc all locations

  • Storage Type

    general purpose warehouse

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    5000.0 dc all locations

  • Switch Current Rating And Type In Amps

    5.0 ac and 1.0 dc

  • Trip Release Characteristic

    time delay all locations

  • Actuator Function

    trip-reset

  • Internal Trip Release Configuration

    series trip all locations

  • Switch Voltage Rating And Type In Volts

    125.0 ac and 50.0 dc

  • Trip Delay Time In Seconds Per Rated Continuous Current

    2.000 minimum at 200 pct all locations and 6.500 maximum at 200 pct all locations

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    0.995 inches minimum and 1.057 inches maximum

  • Boss Height

    0.209 inches minimum and 0.229 inches maximum

  • Mounting Slot Width

    0.178 inches nominal

  • Center To Center Distance Between Terminals Parallel To Length

    3.516 inches minimum and 3.578 inches maximum

  • Thread Quantity Per Inch

    32

  • Trip Release Method

    magnetic-hydraulic all locations

  • Body Style

    multipole-multiple actuator type

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0 all locations

  • Mounting Surface To Terminal End Distance

    3.172 inches minimum and 3.296 inches maximum

  • Switch Contact Arrangement

    single pole, double throw

  • Inclosure Protection Type For Which Designed

    fungus resistant and moisture resistant

  • Nominal Thread Size

    0.138 inches

  • Unthreaded Mounting Hole Diameter

    0.164 inches nominal

  • Main Contact Tripping Mechanism Type

    trip free

  • Body Height

    2.609 inches nominal

  • Arc Quenching Method

    magnetic blowout

  • Body Length

    5.769 inches minimum and 5.831 inches maximum

  • Mounting Facility Type And Quantity

    2 unthreaded hole and 4 threaded hole and 2 slot

  • Operating Voltage Type And Rating Per Pole In Volts

    125.0 dc all locations

  • Manual Actuator Type And Quantity

    2 toggle

  • Unpackaged Unit Weight

    19.000 ounces

  • Auxiliary Switch Function And Quantity

    1 alarm

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    2.719 inches minimum and 2.781 inches maximum

  • Terminal Type And Quantity

    4 threaded stud

  • Center To Center Distance Between Terminals Parallel To Width

    0.995 inches minimum and 1.057 inches maximum

  • External Actuator Linkage Arrangement

    one and two linked

  • Switch Location And Position Designation

    internal at pole one

  • Body Width

    2.041 inches minimum and 2.103 inches maximum

  • Case Material

    plastic

Related Manufacturers

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...