NSN: 5925-01-157-4599

Circuit Breakers

CIRCUIT BREAKER

5925 - Circuit Breakers

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Body Length

    1.985 inches minimum and 2.015 inches maximum

  • Body Width

    0.745 inches minimum and 0.755 inches maximum

  • Case Material

    plastic

  • Arc Quenching Method

    magnetic blowout

  • Mounting Facility Type And Quantity

    2 threaded hole

  • Maximum Continuous Load Current Rating Per Pole

    1.0 amperes ac

  • Operating Voltage Type And Rating Per Pole In Volts

    250.0 ac

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    1.655 inches minimum and 1.665 inches maximum

  • Fragility Factor

    moderately rugged

  • Boss Height

    0.125 inches minimum and 0.135 inches maximum

  • Mounting Surface To Terminal End Distance

    1.875 inches minimum and 1.885 inches maximum

  • Storage Type

    general purpose warehouse

  • Special Handling Feature

    magnetic

  • Thread Quantity Per Inch

    32

  • Circuit Protection Type

    overcurrent

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0

  • Main Contact Tripping Mechanism Type

    trip free

  • Manual Actuator Type And Quantity

    1 toggle

  • Internal Trip Release Configuration

    series trip

  • Frequency In Hertz

    50.0 or b60.0

  • Unpackaged Unit Weight

    2.500 ounces

  • Thread Series Designator

    unc

  • Terminal Type And Quantity

    2 tab,solder lug

  • Center To Center Distance Between Terminals Parallel To Length

    1.555 inches minimum and 1.565 inches maximum

  • Pole Quantity

    1

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    5000.0 ac

  • Trip Release Method

    magnetic-hydraulic

  • Trip Release Characteristic

    time delay

  • Reset Method

    manual

  • Actuator Function

    trip-reset

  • Actuator Position Designation

    at pole one

  • Nominal Thread Size

    0.138 inches

  • Trip Delay Time In Seconds Per Rated Continuous Current

    0.190 minimum at 200 pct and 1.900 maximum at 200 pct

  • Inclosure Protection Type For Which Designed

    fungus resistant and moisture resistant

Related Manufacturers

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...