NSN: 5925-01-157-6634

Circuit Breakers

CIRCUIT BREAKER

5925 - Circuit Breakers

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Body Style

    9b multipole-single actuator type

  • Center To Center Distance Between Terminals Parallel To Length

    1.530 inches nominal

  • Thread Quantity Per Inch

    32

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    5000.0 ac first location

  • Circuit Protection Type

    overcurrent first location

  • Circuit Protection Type

    overvoltage second location

  • Trip Release Method

    magnetic-hydraulic first location

  • Trip Release Characteristic

    instantaneous second location

  • Reset Method

    manual

  • Actuator Function

    trip-reset

  • Actuator Position Designation

    at pole one

  • Internal Trip Release Configuration

    shunt trip first location

  • Nominal Thread Size

    0.138 inches

  • Inclosure Protection Type For Which Designed

    corrosion resistant and moisture resistant and shock resistant and vibration resistant

  • Frequency In Hertz

    50.0 or 60.0

  • Body Length

    2.000 inches nominal

  • Body Width

    1.515 inches maximum

  • Body Height

    2.000 inches maximum

  • Case Material

    plastic

  • Center To Center Distance Between Terminals Parallel To Width

    0.750 inches nominal

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    1.660 inches nominal

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    0.750 inches nominal

  • Fragility Factor

    moderately rugged

  • Boss Height

    0.130 inches nominal

  • Pole Quantity

    2

  • Mounting Facility Type And Quantity

    4 threaded hole

  • Storage Type

    general purpose warehouse

  • Special Handling Feature

    magnetic

  • Maximum Continuous Load Current Rating Per Pole

    5.0 amperes ac first location

  • Operating Voltage Type And Rating Per Pole In Volts

    250.0 ac first location

  • Trip Release Characteristic

    time delay first location

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0

  • Main Contact Tripping Mechanism Type

    trip free

  • Manual Actuator Type And Quantity

    1 toggle

  • Internal Trip Release Configuration

    relay trip second location

  • Trip Delay Time In Seconds Per Rated Continuous Current

    0.130 minimum at 200 pct and 1.300 maximum at 200 pct first location

  • Thread Series Designator

    unc

  • Terminal Type And Quantity

    7 tab, solder lug

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...