Technical Characteristics

  • Thread Quantity Per Inch

    32

  • Mounting Facility Type And Quantity

    1 threaded bushing

  • Pole Quantity

    1

  • Center To Center Distance Between Terminals Parallel To Length

    1.341 inches nominal

  • Body Width

    0.656 inches nominal

  • Body Length

    1.781 inches nominal

  • Bushing Length

    0.290 inches nominal

  • Trip Delay Time In Seconds Per Rated Continuous Current

    0.090 minimum at 200 pct single location and 0.900 maximum at 200 pct and 0.005 minimum at 400 pct and 0.009 maximum at 400 pct

  • Nominal Thread Size

    0.469 inches

  • Actuator Function

    trip-reset

  • Ultimate Trip Time Per Pole In Seconds

    0.500 minimum single location and 2.000 maximum

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    800.0 ac single location

  • Mounting Surface To Terminal End Distance

    1.669 inches nominal

  • Case Material

    plastic

  • Body Style

    1a single pole type

  • Terminal Type And Quantity

    2 screw and 3 tab, solder lug

  • Thread Series Designator

    uns

  • Frequency In Hertz

    400.0 single location

  • Special Features

    operating altitude 60000 ft; temp range m54 to 71 deg c

  • Inclosure Protection Type For Which Designed

    fungus resistant and humidity resistant and sand resistant and dustproof

  • Internal Trip Release Configuration

    shunt trip single location

  • Actuator Position Designation

    at pole one

  • Manual Actuator Type And Quantity

    1 toggle

  • Main Contact Tripping Mechanism Type

    trip free

  • Reset Method

    manual

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    135.0 single location

  • Trip Release Characteristic

    time delay single location

  • Trip Release Method

    magnetic single location

  • Circuit Protection Type

    overcurrent single location

  • Operating Voltage Type And Rating Per Pole In Volts

    120.0 ac single location

  • Maximum Continuous Load Current Rating Per Pole

    100.0 milliamperes ac single location

Related Manufacturers

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...