NSN: 5925-01-161-9560

Circuit Breakers

CIRCUIT BREAKER

5925 - Circuit Breakers

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Case Material

    plastic

  • Pole Quantity

    4

  • Trip Release Method

    magnetic-hydraulic all locations

  • Body Style

    multipole-multiple actuator type

  • Circuit Protection Type

    overcurrent third location

  • Internal Trip Release Configuration

    series trip first location

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    5000.0 ac second location

  • Trip Release Characteristic

    time delay first location

  • Maximum Continuous Load Current Rating Per Pole

    100.0 amperes ac second location

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    2.750 inches nominal

  • Mounting Slot Width

    0.164 inches nominal

  • Manual Actuator Type And Quantity

    4 toggle

  • External Actuator Linkage Arrangement

    one, two, three, and four linked

  • Inclosure Protection Type For Which Designed

    fungus resistant and moisture resistant

  • Terminal Type And Quantity

    8 threaded stud

  • Internal Trip Release Configuration

    series trip second location

  • Center To Center Distance Between Terminals Parallel To Length

    3.546 inches nominal

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    1.032 inches nominal

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    5000.0 ac third location

  • Nominal Thread Size

    0.138 inches

  • Trip Release Characteristic

    time delay second location

  • Internal Trip Release Configuration

    series trip third location

  • Operating Voltage Type And Rating Per Pole In Volts

    240.0 ac first location

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    150.0 first location

  • Main Contact Tripping Mechanism Type

    trip free

  • Arc Quenching Method

    magnetic blowout

  • Trip Release Characteristic

    time delay third location

  • Mounting Facility Type And Quantity

    8 threaded hole and 8 slot

  • Trip Release Characteristic

    instantaneous fourth location

  • Boss Height

    0.218 inches nominal

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    150.0 second location

  • Internal Trip Release Configuration

    shunt trip fourth location

  • Unpackaged Unit Weight

    2.700 pounds

  • Frequency In Hertz

    400.0 all locations

  • Maximum Continuous Load Current Rating Per Pole

    100.0 amperes ac first location

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    150.0 third location

  • Operating Voltage Type And Rating Per Pole In Volts

    240.0 ac second location

  • Body Length

    5.844 inches nominal

  • Operating Voltage Type And Rating Per Pole In Volts

    115.0 dc fourth location

  • Fragility Factor

    moderately rugged

  • Special Handling Feature

    magnetic

  • Operating Voltage Type And Rating Per Pole In Volts

    240.0 ac third location

  • Maximum Continuous Load Current Rating Per Pole

    100.0 amperes ac third location

  • Thread Series Designator

    unc

  • Actuator Position Designation

    at each pole

  • Reset Method

    manual

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    5000.0 ac first location

  • Trip Delay Time In Seconds Per Rated Continuous Current

    20.000 minimum at 200 pct third location and 100.000 maximum at 200 pct third location

  • Body Width

    4.128 inches nominal

  • Circuit Protection Type

    overcurrent first location

  • Storage Type

    general purpose warehouse

  • Actuator Function

    trip-reset

  • Mounting Surface To Terminal End Distance

    2.609 inches nominal

  • Trip Delay Time In Seconds Per Rated Continuous Current

    20.000 minimum at 200 pct second location and 100.000 maximum at 200 pct second location

  • Circuit Protection Type

    overcurrent second location

  • Trip Delay Time In Seconds Per Rated Continuous Current

    20.000 minimum at 200 pct first location and 100.000 maximum at 200 pct first location

  • Thread Quantity Per Inch

    32

  • Center To Center Distance Between Terminals Parallel To Width

    1.032 inches nominal

  • Circuit Protection Type

    undervoltage fourth location

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...