NSN: 5925-01-165-2919

Circuit Breakers

CIRCUIT BREAKER

5925 - Circuit Breakers

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Trip Delay Time In Seconds Per Rated Continuous Current

    0.130 maximum at 600 pct single location and 0.020 minimum at 400 pct single location and 0.050 minimum at 200 pct single location and 0.240 maximum at 400 pct single location and 0.950 maximum at 200 pct single location and 0.060 maximum at 800 pct

  • Mounting Facility Type And Quantity

    2 clip

  • Switch Voltage Rating And Type In Volts

    250.0 ac

  • Switch Current Rating And Type In Amps

    5.0 ac

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    1000.0 ac single location

  • Reset Method

    manual

  • ~1

    single location

  • Boss Height

    0.125 inches nominal

  • Terminal Type And Quantity

    2 tab, solder lug

  • Frequency In Hertz

    400.0 single location

  • Body Style

    single pole type

  • Trip Release Method

    magnetic-hydraulic single location

  • Auxiliary Switch Function And Quantity

    1 alarm

  • Body Width

    0.920 inches nominal

  • Special Features

    flush mtg hardware incl; illuminated handle

  • Case Material

    plastic

  • Ultimate Trip Time Per Pole In Seconds

    0.200 minimum single location and 7.000 maximum single location

  • Switch Terminal Type

    turret

  • Actuator Position Designation

    at pole one

  • Actuator Function

    trip-reset

  • Body Length

    2.000 inches nominal

  • Maximum Continuous Load Current Rating Per Pole

    2.5 amperes ac single location

  • Body Height

    1.770 inches maximum

  • Circuit Protection Type

    overcurrent single location

  • Operating Voltage Type And Rating Per Pole In Volts

    250.0 ac single location

  • Switch Contact Arrangement

    single pole, double throw

  • Pole Quantity

    1

  • Manual Actuator Type And Quantity

    1 toggle

  • Internal Trip Release Configuration

    series trip single location

  • Switch Location And Position Designation

    external at pole one

  • Trip Release Characteristic

    time delay single location

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0 single location

  • Main Contact Tripping Mechanism Type

    trip free

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...