Technical Characteristics

  • Fragility Factor

    moderately rugged

  • Special Handling Feature

    magnetic

  • Circuit Protection Type

    overcurrent all locations

  • Pole Quantity

    2

  • Reset Method

    manual

  • Mounting Facility Type And Quantity

    1 threaded bushing w/panel seal

  • Body Length

    1.562 inches maximum

  • Body Width

    1.250 inches maximum

  • Thread Series Designator

    unef

  • Switch Voltage Rating And Type In Volts

    120.0 ac and 50.0 dc

  • Auxiliary Switch Function And Quantity

    1 alarm

  • Trip Delay Time In Seconds Per Rated Continuous Current

    0.070 minimum at 200 pct all locations and 0.700 maximum at 200 pct all locations

  • Inclosure Protection Type For Which Designed

    shockproof and hermetically sealed and vibrationproof

  • Bushing Length

    0.380 inches maximum

  • Case Material

    plastic

  • Maximum Continuous Load Current Rating Per Pole

    10.0 amperes ac first location and 10.0 amperes dc first location

  • Storage Type

    general purpose warehouse

  • Switch Terminal Type

    wire hook

  • Maximum Continuous Load Current Rating Per Pole

    5.0 amperes ac second location and 5.0 amperes dc second location

  • Switch Location And Position Designation

    internal at pole two

  • Trip Release Characteristic

    time delay all locations

  • Center To Center Distance Between Terminals Parallel To Width

    0.625 inches nominal

  • Actuator Function

    trip-reset

  • Internal Trip Release Configuration

    series trip all locations

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    300.0 ac all locations and 500.0 dc all locations

  • Operating Voltage Type And Rating Per Pole In Volts

    240.0 ac all locations and 50.0 dc all locations

  • Terminal Type And Quantity

    4 tab w/screw

  • Nominal Thread Size

    0.375 inches

  • Thread Quantity Per Inch

    32

  • Mounting Surface To Terminal End Distance

    1.925 inches maximum

  • Trip Release Method

    magnetic all locations

  • Switch Contact Arrangement

    single pole, double throw

  • Center To Center Distance Between Terminals Parallel To Length

    0.875 inches nominal

  • Body Style

    multipole-single actuator type

  • Manual Actuator Type And Quantity

    1 toggle

  • Frequency In Hertz

    60.0 all locations

  • Actuator Position Designation

    between pole one and two

  • Main Contact Tripping Mechanism Type

    trip free

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    115.0 all locations

  • Arc Quenching Method

    magnetic blowout

  • Unpackaged Unit Weight

    3.600 ounces

  • Switch Current Rating And Type In Amps

    0.5 ac and 0.5 dc

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...