Technical Characteristics
-
Operating Voltage Type And Rating Per Pole In Volts
250.0 ac first location and 90.0 ac first location
-
Fragility Factor
moderately rugged
-
Special Handling Feature
magnetic
-
Pole Quantity
3
-
Circuit Protection Type
overcurrent all locations
-
Actuator Position Designation
at each pole
-
Nominal Thread Size
0.190 inches
-
Reset Method
manual
-
Center To Center Distance Between Terminals Parallel To Width
1.500 inches nominal
-
Thread Series Designator
unf
-
Boss Height
0.208 inches minimum and 0.228 inches maximum
-
Storage Type
general purpose warehouse
-
Trip Release Characteristic
time delay all locations
-
Actuator Function
trip-reset
-
External Actuator Linkage Arrangement
one, two, and three linked
-
Operating Voltage Type And Rating Per Pole In Volts
250.0 ac second location
-
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
1000.0 ac all locations
-
Mounting Facility Type And Quantity
4 threaded hole and 6 unthreaded hole
-
Thread Quantity Per Inch
32
-
Trip Release Method
magnetic-hydraulic all locations
-
Center To Center Distance Between Terminals Parallel To Length
2.797 inches minimum and 2.827 inches maximum
-
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0 all locations
-
Inclosure Protection Type For Which Designed
fungus resistant and moisture resistant
-
Body Height
2.958 inches minimum and 2.978 inches maximum
-
Body Style
multipole-single actuator type
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
1.490 inches minimum and 1.510 inches maximum
-
Internal Trip Release Configuration
series trip second location
-
Operating Voltage Type And Rating Per Pole In Volts
250.0 ac third location
-
Internal Trip Release Configuration
series trip third location
-
Body Width
4.490 inches minimum and 4.510 inches maximum
-
Main Contact Tripping Mechanism Type
trip free
-
Arc Quenching Method
magnetic blowout
-
Internal Trip Release Configuration
series trip w/dual rating first location
-
Maximum Continuous Load Current Rating Per Pole
150.0 amperes ac all locations
-
Trip Delay Time In Seconds Per Rated Continuous Current
15.000 minimum at 200 pct all locations and 95.000 maximum at 200 pct all locations
-
Frequency In Hertz
47.0 all locations or 63.0 all locations
-
Body Length
7.115 inches minimum and 7.135 inches maximum
-
Manual Actuator Type And Quantity
3 toggle
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
4.638 inches minimum and 4.668 inches maximum
-
Unthreaded Mounting Hole Diameter
0.031 inches nominal
-
Case Material
plastic
-
Terminal Type And Quantity
6 threaded stud