NSN: 5925-01-167-0071

Circuit Breakers

CIRCUIT BREAKER

5925 - Circuit Breakers

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Trip Release Method

    magnetic-hydraulic single location

  • Maximum Continuous Load Current Rating Per Pole

    10.0 amperes ac single location

  • Iii Special Handling Feature

    magnetic

  • Iii Storage Type

    general purpose warehouse

  • Mounting Facility Type And Quantity

    2 threaded hole

  • Mounting Surface To Terminal End Distance

    1.843 inches nominal

  • Boss Height

    0.130 inches nominal

  • Iii End Item Identification

    6930-00-322-0839

  • Iii Fragility Factor

    moderately rugged

  • Center To Center Distance Between Terminals Parallel To Length

    1.560 inches nominal

  • Trip Release Characteristic

    time delay single location

  • Reset Method

    manual

  • Actuator Function

    trip-reset

  • Actuator Position Designation

    at pole one

  • Internal Trip Release Configuration

    series trip single location

  • Nominal Thread Size

    0.138 inches

  • Trip Delay Time In Seconds Per Rated Continuous Current

    2.000 minimum at 200 pct and 20.000 maximum at 200 pct single location

  • Inclosure Protection Type For Which Designed

    fungus resistant and moisture resistant

  • Frequency In Hertz

    50.0 or 60.0 single location

  • Thread Series Designator

    unc

  • Body Style

    12a single pole type

  • Body Length

    2.000 inches nominal

  • Body Width

    0.750 inches nominal

  • Case Material

    plastic

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    1.660 inches nominal

  • Pole Quantity

    1

  • Iii Arc Quenching Method

    magnetic blowout

  • Thread Quantity Per Inch

    32

  • Operating Voltage Type And Rating Per Pole In Volts

    250.0 ac single location

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    1000.0 ac single location

  • Circuit Protection Type

    overcurrent single location

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0 single location

  • Main Contact Tripping Mechanism Type

    trip free

  • Manual Actuator Type And Quantity

    1 toggle

  • Iii Unpackaged Unit Weight

    2.500 ounces

  • Terminal Type And Quantity

    2 quick disconnect, male

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...