NSN: 5925-01-168-6090
Circuit Breakers
CIRCUIT BREAKER
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Fragility Factor
moderately rugged
-
Center To Center Distance Between Terminals Parallel To Length
1.515 inches minimum and 1.545 inches maximum
-
Inclosure Protection Type For Which Designed
dustproof
-
Bushing Length
0.610 inches minimum and 0.640 inches maximum
-
Reset Method
manual
-
Nominal Thread Size
0.500 inches
-
Mounting Facility Type And Quantity
1 threaded bushing w/panel seal
-
Actuator Position Designation
at pole one
-
Storage Type
general purpose warehouse
-
Maximum Continuous Load Current Rating Per Pole
15.0 amperes dc single location
-
Actuator Function
trip-reset
-
Trip Release Ambient Temp Rating
40.0 deg celsius nominal single location
-
Nonturn Device Location
at 12 oclock
-
Nonturn Device Diameter
0.141 inches minimum and 0.171 inches maximum
-
Thread Quantity Per Inch
32
-
Body Length
1.985 inches minimum and 2.015 inches maximum
-
Circuit Protection Type
overcurrent single location
-
Pole Quantity
1
-
Manual Actuator Type And Quantity
1 toggle
-
Trip Release Method
thermal-magnetic single location
-
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0 single location
-
Main Contact Tripping Mechanism Type
trip free
-
Arc Quenching Method
magnetic blowout
-
Terminal Type And Quantity
2 tab, solder lug
-
Operating Voltage Type And Rating Per Pole In Volts
65.0 dc single location
-
Mounting Surface To Terminal End Distance
2.232 inches maximum
-
Body Style
single pole type
-
Nonturn Device Radius
0.641 inches minimum and 0.671 inches maximum
-
Body Width
0.735 inches minimum and 0.765 inches maximum
-
Trip Release Characteristic
instantaneous single location
-
Thread Series Designator
un
-
End Item Identification
6920-01-142-2858
-
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
30.0 dc single location
-
Nonturn Device Length
0.115 inches minimum and 0.145 inches maximum
-
Case Material
plastic