NSN: 5925-01-170-1532
Circuit Breakers
CIRCUIT BREAKER
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Inclosure Protection Type For Which Designed
moisture resistant and humidity resistant and fungus resistant and shock resistant and vibration resistant
-
Auxiliary Switch Function And Quantity
1 alarm
-
Maximum Continuous Load Current Rating Per Pole
30.0 amperes ac first location
-
Maximum Continuous Load Current Rating Per Pole
30.0 amperes ac second location
-
Manual Actuator Type And Quantity
4 toggle
-
Case Material
plastic
-
Pole Quantity
4
-
Trip Delay Time In Seconds Per Rated Continuous Current
0.180 minimum at 200 pct all locations and 1.800 maximum at 200 pct all locations
-
Operating Voltage Type And Rating Per Pole In Volts
250.0 ac all locations
-
Boss Height
0.108 inches minimum and 0.172 inches maximum
-
Switch Location And Position Designation
internal at pole four
-
Internal Trip Release Configuration
series trip all locations
-
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
1000.0 ac all locations
-
Body Length
2.468 inches minimum and 2.532 inches maximum
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
2.030 inches minimum and 2.094 inches maximum
-
Thread Quantity Per Inch
32
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
0.722 inches minimum and 0.782 inches maximum
-
Mounting Facility Type And Quantity
8 threaded hole
-
Trip Release Method
magnetic-hydraulic all locations
-
Body Style
multipole-multiple actuator type
-
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0 all locations
-
Switch Voltage Rating And Type In Volts
250.0 ac and 30.0 dc
-
External Actuator Linkage Arrangement
one, two, three, and four linked
-
Switch Contact Arrangement
single pole, double throw
-
Terminal Type And Quantity
8 threaded stud
-
Nominal Thread Size
0.138 inches
-
Frequency In Hertz
60.0 all locations
-
Maximum Continuous Load Current Rating Per Pole
6.0 amperes ac fourth location
-
Main Contact Tripping Mechanism Type
trip free
-
Center To Center Distance Between Terminals Parallel To Width
0.722 inches minimum and 0.782 inches maximum
-
Switch Current Rating And Type In Amps
10.0 ac and 5.0 dc
-
Arc Quenching Method
magnetic blowout
-
Center To Center Distance Between Terminals Parallel To Length
1.906 inches minimum and 1.970 inches maximum
-
Body Width
2.968 inches minimum and 3.032 inches maximum
-
Mounting Surface To Terminal End Distance
2.688 inches minimum and 2.752 inches maximum
-
Fragility Factor
moderately rugged
-
Maximum Continuous Load Current Rating Per Pole
20.0 amperes ac third location
-
Switch Terminal Type
tab, solder lug
-
Circuit Protection Type
overcurrent all locations
-
Thread Series Designator
unc
-
Actuator Position Designation
at each pole
-
Reset Method
manual
-
Storage Type
general purpose warehouse
-
Trip Release Characteristic
time delay all locations
-
Actuator Function
trip-reset