NSN: 5925-01-170-2306
Circuit Breakers
CIRCUIT BREAKER
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Mounting Facility Type And Quantity
2 clip
-
Reset Method
manual
-
Ultimate Trip Time Per Pole In Seconds
0.200 minimum single location and 7.000 maximum single location
-
Switch Terminal Type
turret
-
Actuator Position Designation
at pole one
-
Case Material
plastic
-
Special Features
flush mtg hardware incl; illuminated handle
-
Maximum Continuous Load Current Rating Per Pole
1.5 amperes dc single location
-
Body Width
0.920 inches nominal
-
Switch Current Rating And Type In Amps
3.0 dc
-
Trip Delay Time In Seconds Per Rated Continuous Current
0.020 minimum at 400 pct single location and 0.050 minimum at 200 pct single location and 0.950 maximum at 200 pct single location and 0.240 maximum at 400 pct single location
-
Auxiliary Switch Function And Quantity
1 alarm
-
Trip Release Method
magnetic-hydraulic single location
-
Body Style
single pole type
-
Terminal Type And Quantity
2 tab, solder lug
-
Operating Voltage Type And Rating Per Pole In Volts
50.0 dc single location
-
Boss Height
0.125 inches nominal
-
Main Contact Tripping Mechanism Type
trip free
-
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0 single location
-
Trip Release Characteristic
time delay single location
-
Switch Location And Position Designation
external at pole one
-
Internal Trip Release Configuration
series trip single location
-
Manual Actuator Type And Quantity
1 toggle
-
Pole Quantity
1
-
Switch Contact Arrangement
single pole, double throw
-
Circuit Protection Type
overcurrent single location
-
Body Height
1.770 inches maximum
-
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
1000.0 dc single location
-
Body Length
2.000 inches nominal
-
Actuator Function
trip-reset
-
Switch Voltage Rating And Type In Volts
50.0 dc