NSN: 5925-01-170-5763

Circuit Breakers

CIRCUIT BREAKER

5925 - Circuit Breakers

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Unthreaded Mounting Hole Diameter

    0.188 inches nominal

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    4.750 inches nominal

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    1.375 inches nominal

  • Boss Height

    0.219 inches nominal

  • Pole Quantity

    3

  • Maximum Continuous Load Current Rating Per Pole

    40.0 amperes ac

  • Circuit Protection Type

    overcurrent

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    150.0

  • Manual Actuator Type And Quantity

    1 toggle

  • Actuator Position Designation

    at pole two

  • Unpackaged Unit Weight

    4.500 pounds

  • Body Style

    multipole-single actuator type

  • Body Length

    6.000 inches nominal

  • Case Material

    plastic

  • Body Width

    4.125 inches nominal

  • Body Height

    3.375 inches nominal

  • Center To Center Distance Between Terminals Parallel To Length

    5.062 inches nominal

  • Center To Center Distance Between Terminals Parallel To Width

    1.375 inches nominal

  • Mounting Facility Type And Quantity

    4 unthreaded hole

  • Storage Type

    general purpose warehouse

  • Operating Voltage Type And Rating Per Pole In Volts

    240.0 ac

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    10000.0 ac

  • Trip Release Method

    thermal-magnetic

  • Trip Release Characteristic

    time delay

  • Reset Method

    manual

  • Main Contact Tripping Mechanism Type

    trip free

  • Actuator Function

    trip-reset

  • Trip Delay Time In Seconds Per Rated Continuous Current

    28.000 minimum at 200 pct and 75.000 maximum at 200 pct

  • Inclosure Protection Type For Which Designed

    fungus resistant

  • Trip Release Ambient Temp Rating

    40.0 deg celsius nominal

  • Frequency In Hertz

    400.0

  • Terminal Type And Quantity

    6 compression

Related Manufacturers

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...