NSN: 5925-01-171-1671
Circuit Breakers
CIRCUIT BREAKER
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Operating Voltage Type And Rating Per Pole In Volts
240.0 ac all locations
-
Thread Quantity Per Inch
32
-
Mounting Facility Type And Quantity
4 threaded hole
-
Actuator Function
trip-reset
-
Trip Release Characteristic
time delay all locations
-
Storage Type
general purpose warehouse
-
Trip Delay Time In Seconds Per Rated Continuous Current
10.000 nominal at 500 pct first location
-
Switch Terminal Type
turret
-
Reset Method
manual
-
Actuator Position Designation
at each pole
-
Thread Series Designator
unc
-
Pole Quantity
2
-
Mounting Surface To Terminal End Distance
3.765 inches nominal
-
Circuit Protection Type
overcurrent all locations
-
Special Handling Feature
magnetic
-
Terminal Type And Quantity
5 threaded stud
-
Fragility Factor
moderately rugged
-
Case Material
plastic
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
1.032 inches nominal
-
External Actuator Linkage Arrangement
one and two linked
-
Body Width
2.063 inches nominal
-
Unpackaged Unit Weight
11.000 ounces
-
Boss Height
0.220 inches nominal
-
Maximum Continuous Load Current Rating Per Pole
7.0 amperes ac all locations
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
2.750 inches nominal
-
Auxiliary Switch Function And Quantity
1 alarm
-
Body Length
4.750 inches nominal
-
Manual Actuator Type And Quantity
2 toggle
-
Frequency In Hertz
50.0 all locations or 60.0 all locations
-
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
5000.0 ac all locations
-
Inclosure Protection Type For Which Designed
general purpose
-
Internal Trip Release Configuration
shunt trip first location
-
Trip Delay Time In Seconds Per Rated Continuous Current
1.000 nominal at 400 pct second location
-
Arc Quenching Method
magnetic blowout
-
Center To Center Distance Between Terminals Parallel To Length
3.550 inches nominal
-
Main Contact Tripping Mechanism Type
trip free
-
Switch Location And Position Designation
external at pole one
-
Nominal Thread Size
0.138 inches
-
Internal Trip Release Configuration
series trip second location
-
Switch Voltage Rating And Type In Volts
250.0 ac and 50.0 dc
-
Switch Current Rating And Type In Amps
2.5 ac and 1.0 dc
-
Switch Contact Arrangement
single pole, double throw
-
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0 all locations
-
Body Style
multipole-multiple actuator type
-
Trip Release Method
magnetic-hydraulic all locations
-
Center To Center Distance Between Terminals Parallel To Width
1.032 inches nominal