NSN: 5925-01-173-1761
Circuit Breakers
CIRCUIT BREAKER
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Body Style
1a single pole type
-
Body Length
1.100 inches maximum
-
Body Width
0.781 inches maximum
-
Mounting Surface To Terminal End Distance
1.312 inches nominal
-
Pole Quantity
1
-
Maximum Continuous Load Current Rating Per Pole
35.0 amperes ac single location
-
Operating Voltage Type And Rating Per Pole In Volts
120.0 ac single location
-
Circuit Protection Type
overcurrent single location
-
Reset Method
manual
-
Main Contact Tripping Mechanism Type
trip free
-
Manual Actuator Type And Quantity
1 push-pull
-
Actuator Function
trip-reset
-
Nominal Thread Size
0.469 inches
-
Trip Delay Time In Seconds Per Rated Continuous Current
4.000 minimum at 200 pct and 20.000 maximum at 200 pct and 0.400 minimum at 500 pct and 1.700 maximum at 500 pct and 0.100 minimum at 1000 pct and 0.400 maximum at 1000 pct single location
-
Trip Release Ambient Temp Rating
25.0 deg celsius nominal single location
-
Frequency In Hertz
400.0 single location
-
Terminal Type And Quantity
2 screw
-
Thread Pitch Diameters
0.444 to 0.447 inches
-
Bushing Length
0.250 inches nominal
-
Case Material
plastic
-
Center To Center Distance Between Terminals Parallel To Length
0.704 inches nominal
-
Mounting Facility Type And Quantity
1 threaded bushing
-
Thread Quantity Per Inch
32
-
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
2000.0 ac single location
-
Trip Release Method
thermal single location
-
Trip Release Characteristic
time delay single location
-
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
138.0 single location
-
Actuator Position Designation
at pole one
-
Internal Trip Release Configuration
series trip single location
-
Thread Series Designator
uns