NSN: 5925-01-173-1763
Circuit Breakers
CIRCUIT BREAKER
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Case Material
plastic
-
Thread Series Designator
uns
-
Nominal Thread Size
0.469 inches
-
Thread Pitch Diameters
+0.444/+0.447 inches
-
Trip Release Ambient Temp Rating
-55.0 deg celsius minimum single location and 121.0 deg celsius maximum single location
-
Body Width
0.781 inches maximum
-
Terminal Type And Quantity
2 tab w/screw
-
Trip Delay Time In Seconds Per Rated Continuous Current
4.000 minimum at 200 pct single location and 20.000 maximum at 200 pct single location
-
Maximum Continuous Load Current Rating Per Pole
35.0 amperes ac single location and 35.0 amperes dc single location
-
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
138.0 single location
-
Mounting Surface To Terminal End Distance
1.218 inches nominal
-
Body Style
single pole type
-
Center To Center Distance Between Terminals Parallel To Length
0.704 inches nominal
-
Frequency In Hertz
400.0 single location
-
Body Length
1.100 inches maximum
-
Main Contact Tripping Mechanism Type
trip free
-
Trip Release Characteristic
time delay single location
-
Operating Voltage Type And Rating Per Pole In Volts
120.0 ac single location and 28.0 dc single location
-
Internal Trip Release Configuration
series trip single location
-
Pole Quantity
1
-
Mounting Facility Type And Quantity
1 threaded bushing
-
Trip Release Method
thermal single location
-
Circuit Protection Type
overcurrent single location
-
Thread Quantity Per Inch
32
-
Manual Actuator Type And Quantity
1 push button
-
Actuator Function
trip-reset
-
Actuator Position Designation
at pole one
-
Reset Method
manual
-
Inclosure Protection Type For Which Designed
shock resistant and corrosion resistant and vibration resistant and dusttight and humidity resistant and explosion proof
-
Bushing Length
0.250 inches nominal
-
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
2000.0 ac single location and 6000.0 dc single location