Technical Characteristics

  • Bushing Length

    0.480 inches minimum and 0.510 inches maximum

  • Body Width

    2.265 inches maximum

  • Nonturn Device Radius

    0.641 inches minimum and 0.671 inches maximum

  • Nonturn Device Length

    0.115 inches minimum and 0.145 inches maximum

  • Switch Contact Arrangement

    single pole, double throw

  • Fragility Factor

    moderately rugged

  • Arc Quenching Method

    magnetic blowout

  • Mounting Facility Type And Quantity

    1 threaded bushing w/panel seal

  • Storage Type

    general purpose warehouse

  • Thread Quantity Per Inch

    32

  • Maximum Continuous Load Current Rating Per Pole

    2.5 amperes ac all locations

  • Operating Voltage Type And Rating Per Pole In Volts

    240.0 ac all locations

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    1000.0 ac all locations

  • Trip Release Method

    magnetic all locations

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    150.0 all locations

  • Reset Method

    manual

  • Main Contact Tripping Mechanism Type

    trip free

  • Manual Actuator Type And Quantity

    1 toggle

  • Actuator Function

    trip-reset

  • Internal Trip Release Configuration

    series trip all locations

  • Switch Location And Position Designation

    internal at pole three

  • Inclosure Protection Type For Which Designed

    fungus resistant and moisture resistant and salt spray proof and shock resistant and vibration resistant

  • Switch Current Rating And Type In Amps

    5.0 ac and 3.0 dc

  • Switch Voltage Rating And Type In Volts

    240.0 ac and 50.0 dc

  • Thread Series Designator

    un

  • Terminal Type And Quantity

    6 screw

  • Body Style

    1b multipole-single actuator type

  • Body Length

    1.985 inches minimum and 2.015 inches maximum

  • Case Material

    plastic

  • Center To Center Distance Between Terminals Parallel To Length

    1.515 inches minimum and 1.545 inches maximum

  • Center To Center Distance Between Terminals Parallel To Width

    0.735 inches minimum and 0.765 inches maximum

  • Nonturn Device Diameter

    0.151 inches minimum and 0.161 inches maximum

  • Mounting Surface To Terminal End Distance

    2.232 inches maximum

  • Pole Quantity

    3

  • Special Handling Feature

    magnetic

  • Circuit Protection Type

    overcurrent all locations

  • Trip Release Characteristic

    time delay all locations

  • Actuator Position Designation

    at pole two

  • Auxiliary Switch Function And Quantity

    1 alarm

  • Nominal Thread Size

    0.500 inches

  • Trip Delay Time In Seconds Per Rated Continuous Current

    2.100 minimum at 200 pct all locations and 20.000 maximum at 200 pct

  • Switch Terminal Type

    tab, solder lug

  • Frequency In Hertz

    400.0 all locations

  • Unpackaged Unit Weight

    9.000 ounces

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.