NSN: 5925-01-176-1621

Circuit Breakers

CIRCUIT BREAKER

5925 - Circuit Breakers

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Thread Pitch Diameters

    0.4752 to 0.4787 inches

  • Body Style

    1b multipole-single actuator type

  • Bushing Length

    0.625 inches nominal

  • Body Length

    2.000 inches nominal

  • Body Width

    2.250 inches nominal

  • Nonturn Device Length

    0.130 inches nominal

  • Switch Contact Arrangement

    single pole, double throw

  • Pole Quantity

    3

  • Arc Quenching Method

    magnetic blowout

  • Mounting Facility Type And Quantity

    1 threaded bushing w/panel seal

  • Storage Type

    general purpose warehouse

  • Thread Quantity Per Inch

    32

  • Operating Voltage Type And Rating Per Pole In Volts

    240.0 ac all locations

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    2100.0 ac all locations

  • Circuit Protection Type

    overcurrent all locations

  • Trip Release Method

    magnetic-hydraulic all locations

  • Reset Method

    manual

  • Main Contact Tripping Mechanism Type

    trip free

  • Actuator Function

    trip-reset

  • Internal Trip Release Configuration

    series trip all locations

  • Inclosure Protection Type For Which Designed

    hermetically sealed and shock resistant and vibration resistant

  • Thread Series Designator

    un

  • Case Material

    plastic

  • Center To Center Distance Between Terminals Parallel To Length

    1.530 inches nominal

  • Center To Center Distance Between Terminals Parallel To Width

    0.750 inches nominal

  • Nonturn Device Location

    at 12 oclock and at 9 oclock and at 3 oclock

  • Nonturn Device Radius

    0.656 inches nominal

  • Nonturn Device Diameter

    0.151 inches minimum and 0.161 inches maximum

  • Fragility Factor

    moderately rugged

  • Mounting Surface To Terminal End Distance

    2.232 inches maximum

  • Special Handling Feature

    magnetic

  • Maximum Continuous Load Current Rating Per Pole

    5.0 amperes ac all locations

  • Trip Release Characteristic

    time delay all locations

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    115.0 all locations

  • Manual Actuator Type And Quantity

    1 toggle

  • Actuator Position Designation

    at pole two

  • Auxiliary Switch Function And Quantity

    1 alarm

  • Nominal Thread Size

    0.500 inches

  • Switch Location And Position Designation

    internal at pole one

  • Trip Delay Time In Seconds Per Rated Continuous Current

    2.100 minimum at 200 pct all locations and 20.000 maximum at 200 pct

  • Switch Terminal Type

    quick disconnect, male

  • Switch Current Rating And Type In Amps

    10.0 ac and 5.0 dc

  • Switch Voltage Rating And Type In Volts

    250.0 ac and 30.0 dc

  • Frequency In Hertz

    400.0 all locations

  • Unpackaged Unit Weight

    9.000 ounces

  • Terminal Type And Quantity

    6 tab w/screw

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...