Technical Characteristics

  • Trip Delay Time In Seconds Per Rated Continuous Current

    7.000 maximum at 200 pct all locations

  • Inclosure Protection Type For Which Designed

    vibration resistant

  • Frequency In Hertz

    60.0 all locations

  • Terminal Type And Quantity

    4 tab w/screw

  • Inclosure Protection Type For Which Designed

    shock resistant and

  • Frequency In Hertz

    50.0 or

  • Iii Unpackaged Unit Weight

    3.600 ounces

  • Thread Series Designator

    unef

  • Thread Pitch Diameters

    0.3503 to 0.3537 inches

  • Bushing Length

    0.380 inches maximum

  • Body Length

    1.562 inches maximum

  • Body Width

    1.281 inches maximum

  • Case Material

    metal

  • Center To Center Distance Between Terminals Parallel To Width

    0.625 inches nominal

  • Iii Nonturn Device Radius

    0.625 inches nominal

  • Iii Nonturn Device Diameter

    0.250 inches nominal

  • Iii Fragility Factor

    moderately rugged

  • Pole Quantity

    2

  • Mounting Facility Type And Quantity

    1 threaded bushing w/panel seal

  • Iii Special Handling Feature

    magnetic

  • Thread Quantity Per Inch

    32

  • Operating Voltage Type And Rating Per Pole In Volts

    240.0 ac all locations

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    1000.0 ac all locations

  • Trip Release Characteristic

    time delay all locations

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    115.0 all locations

  • Manual Actuator Type And Quantity

    1 toggle

  • Actuator Function

    trip-reset

  • Internal Trip Release Configuration

    series trip all locations

  • Body Style

    1b multipole-single actuator type

  • Center To Center Distance Between Terminals Parallel To Length

    0.875 inches nominal

  • Iii Nonturn Device Location

    at 3 oclock and

  • Iii Nonturn Device Location

    at 9 oclock

  • Mounting Surface To Terminal End Distance

    1.780 inches maximum

  • Iii Arc Quenching Method

    magnetic blowout

  • Iii Storage Type

    general purpose warehouse

  • Maximum Continuous Load Current Rating Per Pole

    5.0 amperes ac all locations

  • Circuit Protection Type

    overcurrent all locations

  • Trip Release Method

    magnetic all locations

  • Reset Method

    manual

  • Main Contact Tripping Mechanism Type

    trip free

  • Actuator Position Designation

    between pole one and two

  • Nominal Thread Size

    0.375 inches

  • Trip Delay Time In Seconds Per Rated Continuous Current

    1.150 minimum at 200 pct and

  • Inclosure Protection Type For Which Designed

    hermetically sealed and

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...