NSN: 5925-01-179-1451
Circuit Breakers
CIRCUIT BREAKER
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
1.026 inches nominal
-
Storage Type
general purpose warehouse
-
Special Handling Feature
magnetic
-
Body Style
9c multipole-multiple actuator type
-
Body Length
5.125 inches nominal
-
Body Width
3.108 inches maximum
-
Body Height
3.550 inches nominal
-
Case Material
plastic
-
Center To Center Distance Between Terminals Parallel To Width
1.026 inches nominal
-
Features Provided
high inrush protection
-
Maximum Continuous Load Current Rating Per Pole
60.0 amperes ac all locations
-
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
500.0 ac all locations
-
Circuit Protection Type
overcurrent all locations
-
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0 all locations
-
Manual Actuator Type And Quantity
3 toggle
-
Actuator Position Designation
at each pole
-
External Actuator Linkage Arrangement
one, two, and three linked
-
Internal Trip Release Configuration
series trip second location
-
Internal Trip Release Configuration
series trip third location
-
Switch Location And Position Designation
internal at pole two
-
Trip Delay Time In Seconds Per Rated Continuous Current
2.000 minimum at 200 pct all locations and 18.000 maximum at 200 pct
-
Switch Terminal Type
tab, solder lug
-
Switch Voltage Rating And Type In Volts
28.0 dc
-
Thread Series Designator
unc
-
Center To Center Distance Between Terminals Parallel To Length
3.550 inches nominal
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
2.750 inches nominal
-
Switch Contact Arrangement
single pole, double throw
-
Fragility Factor
moderately rugged
-
Boss Height
0.220 inches nominal
-
Pole Quantity
3
-
Mounting Facility Type And Quantity
6 threaded hole
-
Thread Quantity Per Inch
32
-
Operating Voltage Type And Rating Per Pole In Volts
250.0 ac all locations
-
Trip Release Method
magnetic-hydraulic all locations
-
Trip Release Characteristic
time delay all locations
-
Reset Method
manual
-
Main Contact Tripping Mechanism Type
trip free
-
Actuator Function
trip-reset
-
Auxiliary Switch Function And Quantity
1 alarm
-
Internal Trip Release Configuration
relay trip first location
-
Nominal Thread Size
0.138 inches
-
Inclosure Protection Type For Which Designed
fungus resistant and moisture resistant
-
Switch Current Rating And Type In Amps
0.1 dc
-
Frequency In Hertz
50.0 all locations or 60.0
-
Unpackaged Unit Weight
2.000 pounds
-
Terminal Type And Quantity
8 threaded stud