NSN: 5925-01-179-1452

Circuit Breakers

CIRCUIT BREAKER

5925 - Circuit Breakers

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Bushing Length

    0.380 inches maximum

  • Body Length

    1.562 inches maximum

  • Body Width

    1.937 inches maximum

  • Center To Center Distance Between Terminals Parallel To Length

    0.860 inches minimum and 0.890 inches maximum

  • Nonturn Device Diameter

    0.140 inches nominal

  • Switch Contact Arrangement

    single pole,double throw

  • Fragility Factor

    moderately rugged

  • Pole Quantity

    3

  • Maximum Continuous Load Current Rating Per Pole

    5.0 amperes ac

  • Circuit Protection Type

    overcurrent

  • Trip Release Characteristic

    time delay

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    115.0

  • Reset Method

    manual

  • Main Contact Tripping Mechanism Type

    trip free

  • Manual Actuator Type And Quantity

    1 toggle

  • Actuator Function

    trip-reset

  • Actuator Position Designation

    at pole two

  • Thread Pitch Diameters

    p0.3503/p0.3537 inches

  • Case Material

    metal

  • Center To Center Distance Between Terminals Parallel To Width

    0.610 inches minimum and 0.640 inches maximum

  • Nonturn Device Location

    at 3 oclock and at 9 oclock

  • Nonturn Device Radius

    0.625 inches nominal

  • Nonturn Device Length

    0.130 inches nominal

  • Mounting Surface To Terminal End Distance

    1.780 inches maximum

  • Arc Quenching Method

    magnetic blowout

  • Mounting Facility Type And Quantity

    1 threaded bushing w/panel seal

  • Storage Type

    general purpose warehouse

  • Special Handling Feature

    magnetic

  • Thread Quantity Per Inch

    32

  • Operating Voltage Type And Rating Per Pole In Volts

    240.0 ac

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    1000.0 ac

  • Trip Release Method

    magnetic

  • Internal Trip Release Configuration

    series trip

  • Nominal Thread Size

    0.375 inches

  • Switch Location And Position Designation

    internal at pole two

  • Inclosure Protection Type For Which Designed

    hermetically sealed and shock resistant and vibration resistant

  • Switch Terminal Type

    tab,solder lug

  • Switch Voltage Rating And Type In Volts

    120.0 ac and 50.0 dc

  • Frequency In Hertz

    50.0 or b60.0

  • Thread Series Designator

    unef

  • Terminal Type And Quantity

    6 screw

  • Auxiliary Switch Function And Quantity

    1 alarm

  • Trip Delay Time In Seconds Per Rated Continuous Current

    0.900 minimum at 200 pct and 4.500 maximum at 200 pct

  • Switch Current Rating And Type In Amps

    0.5 ac and 0.5 dc

  • Unpackaged Unit Weight

    5.400 ounces

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...