NSN: 5925-01-181-8984
Circuit Breakers
CIRCUIT BREAKER
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Body Length
1.990 inches minimum and
-
Case Material
plastic
-
Center To Center Distance Between Terminals Parallel To Length
1.550 inches minimum and
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
1.650 inches minimum and
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
1.670 inches maximum
-
Iii Fragility Factor
moderately rugged
-
Mounting Surface To Terminal End Distance
1.630 inches minimum and
-
Mounting Facility Type And Quantity
2 threaded hole
-
Iii Storage Type
general purpose warehouse
-
Iii Special Handling Feature
magnetic
-
Thread Quantity Per Inch
32
-
Operating Voltage Type And Rating Per Pole In Volts
120.0 ac single location
-
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
3000.0 ac single location
-
Circuit Protection Type
overcurrent single location
-
Trip Release Method
magnetic single location
-
Trip Release Characteristic
time delay single location
-
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0 single location
-
Main Contact Tripping Mechanism Type
trip free
-
Trip Delay Time In Seconds Per Rated Continuous Current
2.000 minimum at 200 pct and
-
Trip Delay Time In Seconds Per Rated Continuous Current
20.000 maximum at 200 pct single location
-
Inclosure Protection Type For Which Designed
moisture resistant and
-
Frequency In Hertz
50.0 or
-
Frequency In Hertz
60.0 single location
-
Iii Unpackaged Unit Weight
65.0 grams
-
Thread Series Designator
unc
-
Body Style
12a single pole type
-
Body Length
2.010 inches maximum
-
Body Width
0.755 inches maximum
-
Center To Center Distance Between Terminals Parallel To Length
1.570 inches maximum
-
Boss Height
0.120 inches minimum and
-
Boss Height
0.140 inches maximum
-
Mounting Surface To Terminal End Distance
1.650 inches maximum
-
Pole Quantity
1
-
Maximum Continuous Load Current Rating Per Pole
30.0 amperes ac single location
-
Reset Method
manual
-
Manual Actuator Type And Quantity
1 toggle
-
Actuator Function
trip-reset
-
Actuator Position Designation
at pole one
-
Internal Trip Release Configuration
series trip single location
-
Nominal Thread Size
0.138 inches
-
Inclosure Protection Type For Which Designed
salt spray proof
-
Inclosure Protection Type For Which Designed
shock resistant and
-
Inclosure Protection Type For Which Designed
vibration resistant and
-
Terminal Type And Quantity
2 tab w/screw