NSN: 5925-01-187-0695

Circuit Breakers

CIRCUIT BREAKER

5925 - Circuit Breakers

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Fragility Factor

    moderately rugged

  • Switch Current Rating And Type In Amps

    15.0 ac and 0.25 dc

  • Pole Quantity

    3

  • Circuit Protection Type

    overcurrent all locations

  • Body Width

    4.125 inches nominal

  • Nominal Thread Size

    0.190 inches

  • Reset Method

    manual

  • Auxiliary Switch Function And Quantity

    2 alarm

  • Features Provided

    adjustable trip release

  • Operating Voltage Type And Rating Per Pole In Volts

    500.0 ac all locations and 250.0 dc all locations

  • Adjustable Trip Setting Current Range Per Pole In Amps

    +125.0/+175.0 ac all locations and +300.0/+350.0 dc all locations

  • Thread Series Designator

    unf

  • Body Length

    6.500 inches nominal

  • Maximum Continuous Load Current Rating Per Pole

    25.0 amperes ac all locations and 25.0 amperes dc all locations

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    15000.0 ac all locations and 10000.0 dc all locations

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    3.688 inches nominal

  • Switch Voltage Rating And Type In Volts

    460.0 ac and 250.0 dc

  • Case Material

    plastic

  • Body Height

    3.875 inches nominal

  • Terminal Type And Quantity

    6 threaded stud

  • Switch Location And Position Designation

    internal at pole one and internal at pole three

  • Storage Type

    general purpose warehouse

  • Actuator Function

    trip-reset

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    3.312 inches nominal

  • Switch Terminal Type

    wire lead

  • Trip Release Characteristic

    instantaneous all locations and time delay all locations

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    135.0 all locations

  • Thread Quantity Per Inch

    32

  • Center To Center Distance Between Terminals Parallel To Length

    3.938 inches nominal

  • Trip Release Method

    thermal-magnetic all locations

  • Actuator Position Designation

    at pole two

  • Switch Contact Arrangement

    single pole, double throw

  • Trip Release Ambient Temp Rating

    50.0 deg celsius nominal all locations

  • Body Style

    multipole-single actuator type

  • Manual Actuator Type And Quantity

    1 toggle

  • Frequency In Hertz

    60.0 all locations

  • Boss Height

    0.188 inches nominal

  • Main Contact Tripping Mechanism Type

    trip free

  • Trip Delay Time In Seconds Per Rated Continuous Current

    3600.000 nominal at 250 pct all locations

  • Center To Center Distance Between Terminals Parallel To Width

    1.344 inches nominal

  • Mounting Facility Type And Quantity

    6 threaded stud

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...