Technical Characteristics

  • Actuator Function

    reset

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    140.0 single location

  • Trip Delay Time In Seconds Per Rated Continuous Current

    8.000 minimum at 200 pct single location and 35.000 maximum at 200 pct single location

  • Case Material

    plastic

  • Thread Quantity Per Inch

    28

  • Body Width

    0.560 inches nominal

  • Terminal Type And Quantity

    2 tab w/screw

  • Thread Series Designator

    unef

  • Frequency In Hertz

    60.0 single location

  • Body Style

    single pole type

  • Bushing Length

    0.450 inches nominal

  • Maximum Continuous Load Current Rating Per Pole

    70.0 amperes ac single location and 70.0 amperes dc single location

  • Mounting Surface To Terminal End Distance

    1.620 inches nominal

  • Center To Center Distance Between Terminals Parallel To Length

    0.840 inches nominal

  • Operating Voltage Type And Rating Per Pole In Volts

    250.0 ac single location and 24.0 dc single location

  • Trip Release Ambient Temp Rating

    77.0 deg fahrenheit nominal single location

  • Main Contact Tripping Mechanism Type

    trip free

  • Trip Release Characteristic

    time delay single location

  • Internal Trip Release Configuration

    series trip single location

  • Pole Quantity

    1

  • Inclosure Protection Type For Which Designed

    fungus resistant

  • Mounting Facility Type And Quantity

    1 threaded bushing

  • Trip Release Method

    thermal single location

  • Circuit Protection Type

    overcurrent single location

  • Nominal Thread Size

    0.438 inches

  • Body Length

    1.380 inches nominal

  • Manual Actuator Type And Quantity

    1 push button

  • Storage Type

    general purpose warehouse

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    1000.0 ac single location and 1000.0 dc single location

  • Actuator Position Designation

    at pole one

  • Reset Method

    manual

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...