NSN: 5925-01-190-6718

Circuit Breakers

CIRCUIT BREAKER

5925 - Circuit Breakers

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Body Style

    12a single pole type

  • Body Width

    0.745 inches minimum and 0.755 inches maximum

  • Center To Center Distance Between Terminals Parallel To Length

    1.555 inches minimum and 1.565 inches maximum

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    1.655 inches minimum and 1.665 inches maximum

  • Fragility Factor

    moderately rugged

  • Boss Height

    0.125 inches minimum and 0.135 inches maximum

  • Pole Quantity

    1

  • Storage Type

    general purpose warehouse

  • Thread Quantity Per Inch

    32

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    2000.0 dc single location

  • Trip Release Method

    magnetic-hydraulic single location

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0

  • Manual Actuator Type And Quantity

    1 toggle

  • Actuator Function

    trip-reset

  • Internal Trip Release Configuration

    series trip single location

  • Nominal Thread Size

    0.138 inches

  • Body Length

    1.985 inches minimum and 2.015 inches maximum

  • Case Material

    plastic

  • Mounting Surface To Terminal End Distance

    1.875 inches minimum and 1.885 inches maximum

  • Arc Quenching Method

    magnetic blowout

  • Trip Delay Time In Seconds Per Rated Continuous Current

    0.150 minimum at 200 pct and 1.500 maximum at 200 pct single location

  • Unpackaged Unit Weight

    2.500 ounces

  • Thread Series Designator

    unc

  • Terminal Type And Quantity

    2 quick disconnect, male

  • Mounting Facility Type And Quantity

    2 threaded hole

  • Maximum Continuous Load Current Rating Per Pole

    5.0 amperes dc single location

  • Operating Voltage Type And Rating Per Pole In Volts

    28.0 dc single location

  • Circuit Protection Type

    overcurrent single location

  • Trip Release Characteristic

    time delay single location

  • Reset Method

    manual

  • Main Contact Tripping Mechanism Type

    trip free

  • Actuator Position Designation

    at pole one

  • Inclosure Protection Type For Which Designed

    fungus resistant and moisture resistant

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...