NSN: 5925-01-193-7247

Circuit Breakers

CIRCUIT BREAKER

5925 - Circuit Breakers

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Trip Delay Time In Seconds Per Rated Continuous Current

    0.180 minimum at 200 pct first location and 1.800 maximum at 200 pct first location

  • Nonturn Device Location

    at 6 oclock

  • Thread Series Designator

    un

  • Trip Release Method

    magnetic first location

  • Nonturn Device Radius

    0.656 inches nominal

  • Trip Release Method

    magnetic second location

  • Case Material

    plastic

  • Nominal Thread Size

    0.500 inches

  • Mounting Facility Type And Quantity

    1 threaded bushing w/panel seal

  • Circuit Protection Type

    overcurrent first location

  • Actuator Function

    trip-reset

  • Body Length

    2.000 inches nominal

  • Nonturn Device Diameter

    0.138 inches nominal

  • Terminal Type And Quantity

    4 tab w/screw

  • Thread Quantity Per Inch

    32

  • Internal Trip Release Configuration

    series trip first location

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0 first location

  • Trip Release Characteristic

    time delay first location

  • Actuator Position Designation

    at pole two

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    1500.0 dc first location

  • Body Style

    multipole-single actuator type

  • Internal Trip Release Configuration

    series trip second location

  • Maximum Continuous Load Current Rating Per Pole

    50.0 amperes dc first location

  • Manual Actuator Type And Quantity

    1 toggle

  • Main Contact Tripping Mechanism Type

    trip free

  • Operating Voltage Type And Rating Per Pole In Volts

    36.0 dc second location

  • Circuit Protection Type

    overvoltage second location

  • Center To Center Distance Between Terminals Parallel To Length

    1.530 inches nominal

  • Trip Release Characteristic

    instantaneous second location

  • Mounting Surface To Terminal End Distance

    2.232 inches maximum

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    150.0 second location

  • Operating Voltage Type And Rating Per Pole In Volts

    32.0 dc first location

  • Body Width

    1.515 inches maximum

  • Bushing Length

    0.495 inches nominal

  • Center To Center Distance Between Terminals Parallel To Width

    0.750 inches nominal

  • Pole Quantity

    2

  • Reset Method

    manual

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...