NSN: 5925-01-197-2584

Circuit Breakers

CIRCUIT BREAKER

5925 - Circuit Breakers

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Reset Method

    manual

  • Thread Series Designator

    unc

  • Operating Voltage Type And Rating Per Pole In Volts

    240.0 ac single location

  • Special Handling Feature

    magnetic

  • Switch Terminal Type

    tab, solder lug

  • Fragility Factor

    moderately rugged

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0 single location

  • Trip Release Characteristic

    time delay single location

  • Center To Center Distance Between Terminals Parallel To Length

    3.547 inches nominal

  • Body Width

    1.026 inches nominal

  • Unthreaded Mounting Hole Diameter

    0.164 inches nominal

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    5000.0 ac single location

  • Switch Current Rating And Type In Amps

    10.0 ac and 4.0 dc

  • Nominal Thread Size

    0.138 inches

  • Internal Trip Release Configuration

    series trip single location

  • Manual Actuator Type And Quantity

    1 toggle

  • Pole Quantity

    1

  • Trip Delay Time In Seconds Per Rated Continuous Current

    20.000 minimum at 200 pct single location and 105.000 maximum at 200 pct single location

  • Switch Contact Arrangement

    single pole, double throw

  • Inclosure Protection Type For Which Designed

    fungus resistant

  • Switch Voltage Rating And Type In Volts

    250.0 ac and 30.0 dc

  • Circuit Protection Type

    overcurrent single location

  • Thread Quantity Per Inch

    32

  • Mounting Slot Width

    0.178 inches nominal

  • Mounting Surface To Terminal End Distance

    4.871 inches nominal

  • Actuator Function

    trip-reset

  • Storage Type

    general purpose warehouse

  • Maximum Continuous Load Current Rating Per Pole

    3.0 amperes ac single location

  • Actuator Position Designation

    at pole one

  • Terminal Type And Quantity

    2 threaded stud

  • Case Material

    plastic

  • Switch Location And Position Designation

    internal at pole one

  • Unpackaged Unit Weight

    9.000 ounces

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    2.750 inches nominal

  • Auxiliary Switch Function And Quantity

    1 alarm

  • Mounting Facility Type And Quantity

    2 threaded hole and 1 unthreaded hole and 1 slot

  • Trip Release Method

    magnetic-hydraulic single location

  • Body Style

    single pole type

  • Boss Height

    0.219 inches nominal

  • Body Length

    5.800 inches nominal

  • Frequency In Hertz

    50.0 single location or 60.0 single location

  • Arc Quenching Method

    magnetic blowout

  • Main Contact Tripping Mechanism Type

    trip free

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...