NSN: 5925-01-197-2587

Circuit Breakers

CIRCUIT BREAKER

5925 - Circuit Breakers

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Center To Center Distance Between Terminals Parallel To Width

    1.032 inches nominal

  • Boss Height

    0.218 inches nominal

  • Mounting Facility Type And Quantity

    6 threaded hole and 6 slot

  • Special Handling Feature

    magnetic

  • Maximum Continuous Load Current Rating Per Pole

    20.0 amperes ac

  • Operating Voltage Type And Rating Per Pole In Volts

    240.0 ac

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    1500.0 ac

  • Circuit Protection Type

    overcurrent

  • Trip Release Characteristic

    time delay

  • Reset Method

    manual

  • Manual Actuator Type And Quantity

    3 toggle

  • Actuator Function

    trip-reset

  • Actuator Position Designation

    at each pole

  • External Actuator Linkage Arrangement

    one,two,and three linked

  • Nominal Thread Size

    0.138 inches

  • Switch Location And Position Designation

    internal at pole one

  • Trip Delay Time In Seconds Per Rated Continuous Current

    35.000 minimum at 200 pct and 150.000 maximum at 200 pct

  • Switch Terminal Type

    tab,solder lug

  • Switch Current Rating And Type In Amps

    10.0 ac and 4.0 dc

  • Switch Voltage Rating And Type In Volts

    250.0 ac and 30.0 dc

  • Frequency In Hertz

    400.0

  • Thread Series Designator

    unc

  • Mounting Slot Width

    0.164 inches nominal

  • Body Length

    5.844 inches nominal

  • Case Material

    plastic

  • Center To Center Distance Between Terminals Parallel To Length

    3.546 inches nominal

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    2.750 inches nominal

  • Switch Contact Arrangement

    single pole,double throw

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    1.032 inches nominal

  • Fragility Factor

    moderately rugged

  • Mounting Surface To Terminal End Distance

    2.609 inches nominal

  • Pole Quantity

    3

  • Arc Quenching Method

    magnetic blowout

  • Storage Type

    general purpose warehouse

  • Thread Quantity Per Inch

    32

  • Trip Release Method

    magnetic-hydraulic

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0

  • Main Contact Tripping Mechanism Type

    trip free

  • Auxiliary Switch Function And Quantity

    1 alarm

  • Internal Trip Release Configuration

    series trip

  • Inclosure Protection Type For Which Designed

    fungus resistant

  • Unpackaged Unit Weight

    2.000 pounds

  • Terminal Type And Quantity

    6 threaded stud

  • Body Width

    3.093 inches nominal

Related Manufacturers

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...