NSN: 5925-01-197-4691

Circuit Breakers

CIRCUIT BREAKER

5925 - Circuit Breakers

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Boss Height

    0.187 inches minimum and 0.251 inches maximum

  • Pole Quantity

    3

  • Arc Quenching Method

    magnetic blowout

  • Maximum Continuous Load Current Rating Per Pole

    80.0 amperes ac

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    5000.0 ac

  • Circuit Protection Type

    overcurrent

  • Trip Release Method

    magnetic-hydraulic

  • Trip Release Characteristic

    time delay

  • Reset Method

    manual

  • Manual Actuator Type And Quantity

    3 toggle

  • Actuator Function

    trip-reset

  • Actuator Position Designation

    at each pole

  • Unpackaged Unit Weight

    2.000 pounds

  • Mounting Slot Width

    0.164 inches nominal

  • Body Length

    5.768 inches minimum and 5.832 inches maximum

  • Body Width

    3.046 inches minimum and 3.110 inches maximum

  • Body Height

    2.577 inches minimum and 2.641 inches maximum

  • Case Material

    plastic

  • Center To Center Distance Between Terminals Parallel To Length

    3.515 inches minimum and 3.579 inches maximum

  • Center To Center Distance Between Terminals Parallel To Width

    0.994 inches minimum and 1.058 inches maximum

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    2.718 inches minimum and 2.782 inches maximum

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    0.994 inches minimum and 1.058 inches maximum

  • Fragility Factor

    moderately rugged

  • Mounting Facility Type And Quantity

    6 threaded hole and 6 slot

  • Storage Type

    general purpose warehouse

  • Thread Quantity Per Inch

    32

  • Operating Voltage Type And Rating Per Pole In Volts

    240.0 ac

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0

  • Main Contact Tripping Mechanism Type

    trip free

  • External Actuator Linkage Arrangement

    one,two,and three linked

  • Internal Trip Release Configuration

    series trip

  • Nominal Thread Size

    0.138 inches

  • Trip Delay Time In Seconds Per Rated Continuous Current

    20.000 minimum at 200 pct and 150.000 maximum at 200 pct

  • Inclosure Protection Type For Which Designed

    fungus resistant

  • Frequency In Hertz

    400.0

  • Thread Series Designator

    unc

  • Terminal Type And Quantity

    6 screw

Related Manufacturers

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.