NSN: 5925-01-200-7812

Circuit Breakers

CIRCUIT BREAKER

5925 - Circuit Breakers

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Mounting Facility Type And Quantity

    8 threaded hole and 8 slot

  • Arc Quenching Method

    magnetic blowout

  • Main Contact Tripping Mechanism Type

    trip free

  • Operating Voltage Type And Rating Per Pole In Volts

    240.0 ac first location

  • Internal Trip Release Configuration

    series trip third location

  • Terminal Type And Quantity

    9 threaded stud

  • Nominal Thread Size

    0.138 inches

  • Center To Center Distance Between Terminals Parallel To Length

    3.546 inches nominal

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    150.0 all locations

  • Internal Trip Release Configuration

    series trip second location

  • External Actuator Linkage Arrangement

    one, two, three, and four linked

  • Internal Trip Release Configuration

    series trip first location

  • Body Length

    3.544 inches nominal

  • Body Style

    multipole-multiple actuator type

  • Trip Release Method

    magnetic-hydraulic all locations

  • Center To Center Distance Between Terminals Parallel To Width

    1.032 inches nominal

  • Thread Quantity Per Inch

    32

  • Operating Voltage Type And Rating Per Pole In Volts

    115.0 ac fourth location

  • Trip Delay Time In Seconds Per Rated Continuous Current

    40.000 minimum at 200 pct second location and 105.000 maximum at 200 pct second location

  • Mounting Surface To Terminal End Distance

    2.609 inches nominal

  • Actuator Function

    trip-reset

  • Trip Release Characteristic

    time delay all locations

  • Body Width

    4.128 inches nominal

  • Reset Method

    manual

  • Trip Delay Time In Seconds Per Rated Continuous Current

    40.000 minimum at 200 pct third location and 105.000 maximum at 200 pct third location

  • Actuator Position Designation

    at each pole

  • Thread Series Designator

    unc

  • Maximum Continuous Load Current Rating Per Pole

    100.0 amperes ac third location

  • Inclosure Protection Type For Which Designed

    dustproof

  • Operating Voltage Type And Rating Per Pole In Volts

    240.0 ac third location

  • Circuit Protection Type

    overcurrent all locations

  • Boss Height

    0.218 inches nominal

  • Trip Delay Time In Seconds Per Rated Continuous Current

    0.530 minimum at 200 pct fourth location and 1.500 maximum at 200 pct fourth location

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    5000.0 ac all locations

  • Internal Trip Release Configuration

    shunt trip fourth location

  • Maximum Continuous Load Current Rating Per Pole

    0.0 amperes ac fourth location

  • Frequency In Hertz

    400.0 all locations

  • Maximum Continuous Load Current Rating Per Pole

    100.0 amperes ac first location

  • Maximum Continuous Load Current Rating Per Pole

    100.0 amperes ac second location

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    2.750 inches nominal

  • Mounting Slot Width

    0.164 inches nominal

  • Trip Delay Time In Seconds Per Rated Continuous Current

    40.000 minimum at 200 pct first location and 105.000 maximum at 200 pct first location

  • Manual Actuator Type And Quantity

    4 toggle

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    1.032 inches nominal

  • Case Material

    plastic

  • Pole Quantity

    4

  • Operating Voltage Type And Rating Per Pole In Volts

    240.0 ac second location

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...