NSN: 5925-01-201-7423

Circuit Breakers

CIRCUIT BREAKER

5925 - Circuit Breakers

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Frequency In Hertz

    60.0 all locations

  • Frequency In Hertz

    50.0 or

  • Switch Current Rating And Type In Amps

    0.5 dc

  • Switch Terminal Type

    pin

  • Inclosure Protection Type For Which Designed

    vibration resistant

  • Inclosure Protection Type For Which Designed

    shock resistant and

  • Inclosure Protection Type For Which Designed

    hermetically sealed and

  • Switch Location And Position Designation

    internal at pole two

  • Nominal Thread Size

    0.375 inches

  • Internal Trip Release Configuration

    series trip all locations

  • Auxiliary Switch Function And Quantity

    1 alarm

  • Actuator Position Designation

    at pole two

  • Actuator Function

    trip-reset

  • Manual Actuator Type And Quantity

    1 toggle

  • Main Contact Tripping Mechanism Type

    trip free

  • Trip Release Characteristic

    time delay all locations

  • Operating Voltage Type And Rating Per Pole In Volts

    240.0 ac all locations

  • Maximum Continuous Load Current Rating Per Pole

    20.0 amperes ac all locations

  • Thread Quantity Per Inch

    32

  • Iii Special Handling Feature

    magnetic

  • Mounting Facility Type And Quantity

    1 threaded bushing w/panel seal

  • Pole Quantity

    3

  • Iii Fragility Factor

    moderately rugged

  • Switch Contact Arrangement

    single pole, double throw

  • Iii Nonturn Device Diameter

    0.140 inches nominal

  • Iii Nonturn Device Radius

    0.625 inches nominal

  • Body Width

    1.875 inches maximum

  • Body Length

    1.562 inches maximum

  • Bushing Length

    0.380 inches maximum

  • Body Style

    1b multipole-single actuator type

  • Thread Pitch Diameters

    0.3503 to 0.3537 inches

  • Reset Method

    manual

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0 all locations

  • Trip Release Method

    magnetic all locations

  • Circuit Protection Type

    overcurrent all locations

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    1000.0 dc all locations

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    1000.0 ac and

  • Iii Storage Type

    general purpose warehouse

  • Iii Arc Quenching Method

    magnetic blowout

  • Mounting Surface To Terminal End Distance

    1.780 inches maximum

  • Iii Nonturn Device Length

    0.130 inches nominal

  • Iii Nonturn Device Location

    at 9 oclock

  • Iii Nonturn Device Location

    at 3 oclock and

  • Center To Center Distance Between Terminals Parallel To Width

    0.625 inches nominal

  • Center To Center Distance Between Terminals Parallel To Length

    0.890 inches maximum

  • Center To Center Distance Between Terminals Parallel To Length

    0.860 inches minimum and

  • Case Material

    metal

  • Terminal Type And Quantity

    6 screw

  • Thread Series Designator

    unef

  • Iii Unpackaged Unit Weight

    5.400 ounces

  • Switch Voltage Rating And Type In Volts

    50.0 dc

  • Switch Voltage Rating And Type In Volts

    120.0 ac and

  • Switch Current Rating And Type In Amps

    0.5 ac and

  • Trip Delay Time In Seconds Per Rated Continuous Current

    8.000 maximum at 200 pct all locations

  • Trip Delay Time In Seconds Per Rated Continuous Current

    1.000 minimum at 200 pct and

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...