NSN: 5925-01-202-8344

Circuit Breakers

CIRCUIT BREAKER

5925 - Circuit Breakers

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Body Length

    5.125 inches nominal

  • Case Material

    plastic

  • Center To Center Distance Between Terminals Parallel To Width

    1.026 inches nominal

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    1.026 inches nominal

  • Mounting Surface To Terminal End Distance

    3.550 inches nominal

  • Storage Type

    general purpose warehouse

  • Maximum Continuous Load Current Rating Per Pole

    75.0 amperes ac

  • Operating Voltage Type And Rating Per Pole In Volts

    120.0 dc

  • Operating Voltage Type And Rating Per Pole In Volts

    250.0 ac

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    5000.0 ac

  • Circuit Protection Type

    overcurrent

  • Actuator Position Designation

    at each pole

  • Internal Trip Release Configuration

    series trip

  • Trip Delay Time In Seconds Per Rated Continuous Current

    0.010 minimum at 600 pct and 1.000 maximum at 600 pct

  • Special Features

    special construction,not ul listed or recognized

  • Thread Series Designator

    unc

  • Body Style

    multipole-multiple actuator type

  • Body Width

    4.144 inches nominal

  • Center To Center Distance Between Terminals Parallel To Length

    3.550 inches nominal

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    2.750 inches nominal

  • Fragility Factor

    moderately rugged

  • Boss Height

    0.220 inches nominal

  • Pole Quantity

    4

  • Arc Quenching Method

    magnetic blowout

  • Mounting Facility Type And Quantity

    8 threaded hole

  • Maximum Continuous Load Current Rating Per Pole

    75.0 amperes dc

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    5000.0 dc

  • Trip Release Method

    magnetic-hydraulic

  • Trip Release Characteristic

    time delay

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    138.0

  • Reset Method

    manual

  • Main Contact Tripping Mechanism Type

    trip free

  • Manual Actuator Type And Quantity

    4 toggle

  • Actuator Function

    trip-reset

  • External Actuator Linkage Arrangement

    one,two,three,and four linked

  • Nominal Thread Size

    0.138 inches

  • Inclosure Protection Type For Which Designed

    general purpose

  • Frequency In Hertz

    400.0

  • Terminal Type And Quantity

    8 threaded stud

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...