NSN: 5925-01-202-8350

Circuit Breakers

CIRCUIT BREAKER

5925 - Circuit Breakers

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    2.060 inches nominal

  • Fragility Factor

    moderately rugged

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    1000.0 dc all locations

  • Circuit Protection Type

    overcurrent all locations

  • Pole Quantity

    2

  • Thread Series Designator

    unc

  • Actuator Position Designation

    at each pole

  • Reset Method

    manual

  • Center To Center Distance Between Terminals Parallel To Length

    0.667 inches nominal and 1.440 inches nominal

  • Storage Type

    general purpose warehouse

  • Actuator Function

    trip-reset

  • Mounting Facility Type And Quantity

    4 threaded hole

  • Mounting Surface To Terminal End Distance

    2.437 inches nominal

  • Trip Release Method

    magnetic-hydraulic all locations

  • Body Style

    multipole-multiple actuator type

  • Operating Voltage Type And Rating Per Pole In Volts

    65.0 dc all locations

  • Trip Release Characteristic

    instantaneous first location

  • Internal Trip Release Configuration

    relay trip first location

  • Case Material

    plastic

  • Body Length

    2.490 inches nominal

  • Terminal Type And Quantity

    6 threaded stud

  • Internal Trip Release Configuration

    series trip second location

  • Maximum Continuous Load Current Rating Per Pole

    50.0 amperes dc first location

  • Nominal Thread Size

    0.138 inches

  • Trip Release Characteristic

    time delay second location

  • Maximum Continuous Load Current Rating Per Pole

    30.0 amperes dc second location

  • Main Contact Tripping Mechanism Type

    trip free

  • Trip Delay Time In Seconds Per Rated Continuous Current

    2.500 minimum at 200 pct second location and 8.000 maximum at 200 pct second location

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    0.750 inches nominal

  • Arc Quenching Method

    magnetic blowout

  • Boss Height

    0.675 inches nominal

  • Inclosure Protection Type For Which Designed

    general purpose

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    138.0 all locations

  • Manual Actuator Type And Quantity

    2 toggle

  • Center To Center Distance Between Terminals Parallel To Width

    0.750 inches maximum

  • Body Width

    1.500 inches nominal

  • External Actuator Linkage Arrangement

    one and two linked

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...