NSN: 5925-01-202-9989

Circuit Breakers

CIRCUIT BREAKER

5925 - Circuit Breakers

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Body Style

    multipole-multiple actuator type

  • Case Material

    plastic

  • Center To Center Distance Between Terminals Parallel To Width

    0.740 inches minimum and 0.760 inches maximum

  • Fragility Factor

    moderately rugged

  • Mounting Surface To Terminal End Distance

    2.461 inches minimum and 2.481 inches maximum

  • Mounting Facility Type And Quantity

    8 threaded hole

  • Storage Type

    general purpose warehouse

  • Thread Quantity Per Inch

    32

  • Maximum Continuous Load Current Rating Per Pole

    50.0 amperes dc

  • Operating Voltage Type And Rating Per Pole In Volts

    107.0 dc

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    1000.0 dc

  • Circuit Protection Type

    overcurrent

  • Trip Release Method

    magnetic

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0

  • Main Contact Tripping Mechanism Type

    trip free

  • Manual Actuator Type And Quantity

    4 toggle

  • Internal Trip Release Configuration

    series trip

  • Trip Delay Time In Seconds Per Rated Continuous Current

    10.000 minimum at 200 pct and 85.000 maximum at 200 pct

  • Inclosure Protection Type For Which Designed

    moisture resistant and humidity resistant and shock resistant and vibration resistant

  • Special Features

    interrupt current capacity is 5000 amps when a proper back-up breaker and/or fuse is used in the circuit

  • Frequency In Hertz

    50.0 or b60.0

  • Thread Series Designator

    unc

  • Terminal Type And Quantity

    10 threaded stud

  • Boss Height

    0.130 inches minimum and 0.150 inches maximum

  • Pole Quantity

    4

  • Body Length

    2.499 inches minimum and 2.510 inches maximum

  • Body Width

    2.990 inches minimum and 3.100 inches maximum

  • Center To Center Distance Between Terminals Parallel To Length

    1.928 inches minimum and 1.948 inches maximum

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    2.052 inches minimum and 2.072 inches maximum

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    0.740 inches minimum and 0.760 inches maximum

  • Arc Quenching Method

    magnetic blowout

  • Maximum Continuous Load Current Rating Per Pole

    50.0 amperes ac

  • Operating Voltage Type And Rating Per Pole In Volts

    250.0 ac

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    1000.0 ac

  • Trip Release Characteristic

    time delay

  • Reset Method

    manual

  • Actuator Function

    trip-reset

  • Actuator Position Designation

    at each pole

  • External Actuator Linkage Arrangement

    one,two,three,and four linked

  • Internal Trip Release Configuration

    relay trip

  • Nominal Thread Size

    0.138 inches

  • Unpackaged Unit Weight

    12.500 ounces

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...