NSN: 5925-01-202-9989
Circuit Breakers
CIRCUIT BREAKER
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Body Style
multipole-multiple actuator type
-
Case Material
plastic
-
Center To Center Distance Between Terminals Parallel To Width
0.740 inches minimum and 0.760 inches maximum
-
Fragility Factor
moderately rugged
-
Mounting Surface To Terminal End Distance
2.461 inches minimum and 2.481 inches maximum
-
Mounting Facility Type And Quantity
8 threaded hole
-
Storage Type
general purpose warehouse
-
Thread Quantity Per Inch
32
-
Maximum Continuous Load Current Rating Per Pole
50.0 amperes dc
-
Operating Voltage Type And Rating Per Pole In Volts
107.0 dc
-
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
1000.0 dc
-
Circuit Protection Type
overcurrent
-
Trip Release Method
magnetic
-
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0
-
Main Contact Tripping Mechanism Type
trip free
-
Manual Actuator Type And Quantity
4 toggle
-
Internal Trip Release Configuration
series trip
-
Trip Delay Time In Seconds Per Rated Continuous Current
10.000 minimum at 200 pct and 85.000 maximum at 200 pct
-
Inclosure Protection Type For Which Designed
moisture resistant and humidity resistant and shock resistant and vibration resistant
-
Special Features
interrupt current capacity is 5000 amps when a proper back-up breaker and/or fuse is used in the circuit
-
Frequency In Hertz
50.0 or b60.0
-
Thread Series Designator
unc
-
Terminal Type And Quantity
10 threaded stud
-
Boss Height
0.130 inches minimum and 0.150 inches maximum
-
Pole Quantity
4
-
Body Length
2.499 inches minimum and 2.510 inches maximum
-
Body Width
2.990 inches minimum and 3.100 inches maximum
-
Center To Center Distance Between Terminals Parallel To Length
1.928 inches minimum and 1.948 inches maximum
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
2.052 inches minimum and 2.072 inches maximum
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
0.740 inches minimum and 0.760 inches maximum
-
Arc Quenching Method
magnetic blowout
-
Maximum Continuous Load Current Rating Per Pole
50.0 amperes ac
-
Operating Voltage Type And Rating Per Pole In Volts
250.0 ac
-
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
1000.0 ac
-
Trip Release Characteristic
time delay
-
Reset Method
manual
-
Actuator Function
trip-reset
-
Actuator Position Designation
at each pole
-
External Actuator Linkage Arrangement
one,two,three,and four linked
-
Internal Trip Release Configuration
relay trip
-
Nominal Thread Size
0.138 inches
-
Unpackaged Unit Weight
12.500 ounces