NSN: 5925-01-203-3923

Circuit Breakers

CIRCUIT BREAKER

5925 - Circuit Breakers

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Maximum Continuous Load Current Rating Per Pole

    50.0 amperes dc

  • Arc Quenching Method

    magnetic blowout

  • Fragility Factor

    moderately rugged

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    0.735 inches minimum and 0.765 inches maximum

  • Center To Center Distance Between Terminals Parallel To Width

    0.735 inches minimum and 0.765 inches maximum

  • Case Material

    plastic

  • Body Width

    3.765 inches maximum

  • Body Length

    2.480 inches minimum and 2.500 inches maximum

  • Terminal Type And Quantity

    12 threaded stud

  • Thread Series Designator

    unc

  • Unpackaged Unit Weight

    1.125 pounds

  • Trip Delay Time In Seconds Per Rated Continuous Current

    2.000 minimum at 200 pct and 22.000 maximum at 200 pct

  • Trip Release Duty Cycle

    continuous

  • Nominal Thread Size

    0.138 inches

  • Internal Trip Release Configuration

    series/relay trip

  • Internal Trip Release Configuration

    series trip

  • External Actuator Linkage Arrangement

    one,two,three,four,and five linked

  • Actuator Position Designation

    at each pole

  • Actuator Function

    trip-reset

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0

  • Trip Release Characteristic

    instantaneouss

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    5000.0 ac

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    2000.0 dc

  • Maximum Continuous Load Current Rating Per Pole

    40.0 amperes ac

  • Maximum Continuous Load Current Rating Per Pole

    20.0 amperes ac

  • Thread Quantity Per Inch

    32

  • Storage Type

    general purpose warehouse

  • Mounting Facility Type And Quantity

    10 threaded hole

  • Pole Quantity

    5

  • Mounting Surface To Terminal End Distance

    2.000 inches maximum

  • Boss Height

    0.135 inches minimum and 0.165 inches maximum

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    2.050 inches minimum and 2.070 inches maximum

  • Center To Center Distance Between Terminals Parallel To Length

    1.925 inches minimum and 1.955 inches maximum

  • Frequency In Hertz

    50.0 or b60.0

  • Inclosure Protection Type For Which Designed

    shock resistant and vibration resistant and moisture resistant and corrosion resistant

  • Manual Actuator Type And Quantity

    5 toggle

  • Main Contact Tripping Mechanism Type

    trip free

  • Reset Method

    manual

  • Trip Release Characteristic

    time delay

  • Auxiliary Trip Coil Voltage Type And Rating In Volts

    24.0 dc nominal

  • Trip Release Method

    magnetic

  • Circuit Protection Type

    overcurrent

  • Operating Voltage Type And Rating Per Pole In Volts

    65.0 dc

  • Operating Voltage Type And Rating Per Pole In Volts

    120.0 ac

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.