NSN: 5925-01-203-9373

Circuit Breakers

CIRCUIT BREAKER

5925 - Circuit Breakers

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Trip Release Ambient Temp Rating

    25.0 deg celsius nominal single location

  • Main Contact Tripping Mechanism Type

    trip free

  • Frequency In Hertz

    400.0 single location

  • Center To Center Distance Between Terminals Parallel To Length

    1.173 inches minimum and 1.203 inches maximum

  • Body Style

    single pole type

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    138.0 single location

  • Mounting Surface To Terminal End Distance

    2.202 inches maximum

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    5000.0 ac single location and 2500.0 dc single location

  • Terminal Type And Quantity

    2 tab w/screw

  • Unpackaged Unit Weight

    0.125 pounds

  • Bushing Length

    0.250 inches maximum

  • Body Width

    0.750 inches maximum

  • Nominal Thread Size

    0.469 inches

  • Case Material

    plastic

  • Trip Release Characteristic

    time delay single location

  • Ultimate Trip Time Per Pole In Seconds

    65.000 nominal single location

  • Operating Voltage Type And Rating Per Pole In Volts

    200.0 ac single location and 28.0 dc single location

  • Internal Trip Release Configuration

    series trip single location

  • Pole Quantity

    1

  • Inclosure Protection Type For Which Designed

    fungus resistant and moisture resistant

  • Manual Actuator Type And Quantity

    1 push-pull

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    1.797 inches minimum and 1.827 inches maximum

  • Trip Delay Time In Seconds Per Rated Continuous Current

    30.000 minimum at 200 pct single location and 65.000 maximum at 200 pct single location

  • Trip Release Method

    thermal single location

  • Circuit Protection Type

    overcurrent single location

  • Thread Quantity Per Inch

    32

  • Actuator Function

    trip-reset

  • Storage Type

    general purpose warehouse

  • Actuator Position Designation

    at pole one

  • Mounting Facility Type And Quantity

    1 threaded bushing w/panel seal

  • Reset Method

    manual

  • Thread Series Designator

    unc

  • Body Length

    2.188 inches maximum

  • Maximum Continuous Load Current Rating Per Pole

    50.0 amperes ac single location and 50.0 amperes dc single location

  • Fragility Factor

    moderately rugged

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...