NSN: 5925-01-204-3360

Circuit Breakers

CIRCUIT BREAKER

5925 - Circuit Breakers

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Main Contact Tripping Mechanism Type

    trip free

  • Maximum Continuous Load Current Rating Per Pole

    1.0 amperes ac single location and 1.0 amperes dc single location

  • Frequency In Hertz

    400.0 single location

  • Center To Center Distance Between Terminals Parallel To Length

    1.173 inches minimum and 1.203 inches maximum

  • Body Style

    single pole type

  • Body Length

    1.152 inches maximum

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    150.0 single location

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    5000.0 ac single location and 2500.0 dc single location

  • Terminal Type And Quantity

    2 tab w/screw

  • Unpackaged Unit Weight

    0.125 pounds

  • Bushing Length

    0.250 inches maximum

  • Body Width

    0.750 inches maximum

  • Nominal Thread Size

    0.469 inches

  • End Item Identification

    c18a

  • Thread Series Designator

    uns

  • Case Material

    plastic

  • Fragility Factor

    moderately rugged

  • Mounting Surface To Terminal End Distance

    1.859 inches maximum

  • Reset Method

    manual

  • Mounting Facility Type And Quantity

    1 threaded bushing w/panel seal

  • Actuator Position Designation

    at pole one

  • Precious Material

    silver

  • Storage Type

    general purpose warehouse

  • Actuator Function

    trip-reset

  • Trip Delay Time In Seconds Per Rated Continuous Current

    0.400 minimum at 200 pct single location and 1.800 maximum at 200 pct single location

  • Thread Quantity Per Inch

    32

  • Circuit Protection Type

    overcurrent single location

  • Trip Release Method

    thermal single location

  • Manual Actuator Type And Quantity

    1 push-pull

  • Precious Material And Location

    terminal surface silver

  • Inclosure Protection Type For Which Designed

    fungus resistant and moisture resistant

  • Pole Quantity

    1

  • Internal Trip Release Configuration

    series trip single location

  • Operating Voltage Type And Rating Per Pole In Volts

    200.0 ac single location and 28.0 dc single location

  • Trip Release Characteristic

    time delay single location

  • Trip Release Ambient Temp Rating

    25.0 deg celsius nominal single location

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...