NSN: 5925-01-204-9438

Circuit Breakers

CIRCUIT BREAKER

5925 - Circuit Breakers

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Body Style

    15a single pole type

  • Overall Length

    3.375 inches maximum

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    2.927 inches minimum and 2.947 inches maximum

  • Pole Quantity

    1

  • Features Provided

    trip indicator

  • Ultimate Trip Time Per Pole In Seconds

    360.000 maximum single location

  • Main Contact Tripping Mechanism Type

    nontrip free

  • Internal Trip Release Configuration

    series trip w/remote trip feature single location

  • Reset Actuator Voltage Rating And Type In Volts

    7.5 dc

  • Trip Delay Time In Seconds Per Rated Continuous Current

    13.000 minimum at 200 pct and 60.000 maximum at 200 pct single location

  • Trip Release Ambient Temp Rating

    25.0 deg celsius nominal single location

  • Switch Terminal Type

    wire lead

  • Switch Current Rating And Type In Amps

    15.0 dc

  • Terminal Type And Quantity

    2 tab w/screw

  • Specification/Standard Data

    36659-ls10071 manufacturers specification control

  • Maximum Continuous Load Current Rating Per Pole

    15.0 amperes dc single location

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    2800.0 dc single location

  • Trip Release Method

    thermal single location

  • Trip Release Characteristic

    time delay single location

  • Body Width

    1.250 inches maximum

  • Case Material

    metal

  • Center To Center Distance Between Terminals Parallel To Length

    1.531 inches nominal

  • Unthreaded Mounting Hole Diameter

    0.195 inches minimum and 0.201 inches maximum

  • Switch Contact Arrangement

    single pole, single throw, normally closed

  • Mounting Surface To Terminal End Distance

    4.250 inches nominal

  • Mounting Facility Type And Quantity

    2 unthreaded hole

  • Operating Voltage Type And Rating Per Pole In Volts

    28.0 dc single location

  • Circuit Protection Type

    overcurrent single location

  • Auxiliary Trip Coil Voltage Type And Rating In Volts

    28.0 dc nominal single location

  • Reset Method

    electric

  • Auxiliary Switch Function And Quantity

    1 control

  • Trip Release Duty Cycle

    continuous single location

  • Switch Location And Position Designation

    external at pole one

  • Switch Voltage Rating And Type In Volts

    28.0 dc

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...