NSN: 5925-01-205-2846

Circuit Breakers

CIRCUIT BREAKER

5925 - Circuit Breakers

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Test Data Document

    81349-mil-c-55629 specification

  • Thread Series Designator

    unc

  • Terminal Type And Quantity

    2 threaded stud

  • Body Length

    2.510 inches maximum

  • Body Width

    0.780 inches maximum

  • Center To Center Distance Between Terminals Parallel To Length

    1.660 inches minimum and

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    2.078 inches maximum

  • Boss Height

    0.109 inches minimum and

  • Iii Arc Quenching Method

    magnetic blowout

  • Body Style

    12a single pole type

  • Body Width

    0.730 inches minimum and

  • Case Material

    plastic

  • Center To Center Distance Between Terminals Parallel To Length

    1.960 inches maximum

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    2.046 inches minimum and

  • Switch Contact Arrangement

    single pole, double throw

  • Iii Fragility Factor

    moderately rugged

  • Boss Height

    0.171 inches maximum

  • Mounting Surface To Terminal End Distance

    2.800 inches maximum

  • Pole Quantity

    1

  • Mounting Facility Type And Quantity

    2 threaded hole

  • Thread Quantity Per Inch

    32

  • Maximum Continuous Load Current Rating Per Pole

    40.0 amperes ac single location

  • Operating Voltage Type And Rating Per Pole In Volts

    240.0 ac single location

  • Circuit Protection Type

    overcurrent single location

  • Trip Release Method

    magnetic single location

  • Trip Release Characteristic

    time delay single location

  • Main Contact Tripping Mechanism Type

    trip free

  • Manual Actuator Type And Quantity

    1 toggle

  • Actuator Function

    trip-reset

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    1000.0 ac single location

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0 single location

  • Reset Method

    manual

  • Actuator Position Designation

    at pole one

  • Internal Trip Release Configuration

    series trip single location

  • Auxiliary Switch Function And Quantity

    1 alarm

  • Nominal Thread Size

    0.138 inches

  • Trip Delay Time In Seconds Per Rated Continuous Current

    1.600 maximum at 200 pct single location

  • Inclosure Protection Type For Which Designed

    shock resistant and

  • Inclosure Protection Type For Which Designed

    vibration resistant

  • Switch Current Rating And Type In Amps

    2.0 dc

  • Switch Location And Position Designation

    internal at pole one

  • Trip Delay Time In Seconds Per Rated Continuous Current

    0.130 minimum at 200 pct and

  • Switch Terminal Type

    tab, solder lug

  • Switch Current Rating And Type In Amps

    10.0 ac and

  • Switch Voltage Rating And Type In Volts

    250.0 ac and

  • Switch Voltage Rating And Type In Volts

    50.0 dc

  • Frequency In Hertz

    60.0 single location

  • Specification/Standard Data

    81349-mil-c-55629/2 government specification

  • Iii Storage Type

    general purpose warehouse

  • Definitive Government Spec/Std Reference

    m55629/2-242

  • Manufacturers Code

    81349

  • Non-Definitive Government Spec/Std Reference

    mil-c-55629/2

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...