NSN: 5925-01-205-2852

Circuit Breakers

CIRCUIT BREAKER

5925 - Circuit Breakers

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Body Length

    2.000 inches nominal

  • Case Material

    plastic

  • Center To Center Distance Between Terminals Parallel To Length

    1.530 inches nominal

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    1.660 inches nominal

  • Switch Contact Arrangement

    double pole, double throw

  • Fragility Factor

    moderately rugged

  • Boss Height

    0.130 inches nominal

  • Mounting Surface To Terminal End Distance

    2.000 inches nominal

  • Pole Quantity

    1

  • Arc Quenching Method

    magnetic blowout

  • Mounting Facility Type And Quantity

    2 threaded hole

  • Storage Type

    general purpose warehouse

  • Thread Quantity Per Inch

    32

  • Maximum Continuous Load Current Rating Per Pole

    30.0 amperes ac single location

  • Circuit Protection Type

    overcurrent single location

  • Trip Release Method

    magnetic-hydraulic single location

  • Trip Release Characteristic

    time delay single location

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0

  • Main Contact Tripping Mechanism Type

    trip free

  • Manual Actuator Type And Quantity

    1 toggle

  • Actuator Function

    trip-reset

  • Nominal Thread Size

    0.138 inches

  • Inclosure Protection Type For Which Designed

    fungus resistant

  • Thread Series Designator

    unc

  • Body Style

    12a single pole type

  • Body Width

    0.750 inches nominal

  • Special Handling Feature

    magnetic

  • Operating Voltage Type And Rating Per Pole In Volts

    250.0 ac single location

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    1000.0 ac single location

  • Reset Method

    manual

  • Actuator Position Designation

    at pole one

  • Auxiliary Switch Function And Quantity

    1 alarm

  • Internal Trip Release Configuration

    series trip single location

  • Switch Location And Position Designation

    internal at pole one

  • Trip Delay Time In Seconds Per Rated Continuous Current

    1.500 minimum at 200 pct and 50.000 maximum at 200 pct single location

  • Switch Terminal Type

    quick disconnect, male

  • Switch Current Rating And Type In Amps

    10.0 ac

  • Switch Voltage Rating And Type In Volts

    250.0 ac

  • Frequency In Hertz

    50.0 or 60.0

  • Terminal Type And Quantity

    2 quick disconnect, male

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...