NSN: 5925-01-205-7481
Circuit Breakers
CIRCUIT BREAKER
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Bushing Length
0.040 inches minimum and 0.055 inches maximum
-
Body Width
0.531 inches minimum and 0.593 inches maximum
-
Fragility Factor
moderately rugged
-
Maximum Continuous Load Current Rating Per Pole
35.0 amperes ac
-
Circuit Protection Type
overcurrent
-
Trip Release Method
thermal
-
Trip Release Characteristic
time delay
-
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
138.0
-
Reset Method
manual
-
Main Contact Tripping Mechanism Type
trip free
-
Actuator Function
trip-reset
-
Nominal Thread Size
0.469 inches
-
Trip Release Ambient Temp Rating
25.0 deg celsius maximum
-
Frequency In Hertz
400.0
-
Specification/Standard Data
36659-ls10158 manufacturers standard
-
Body Length
0.730 inches minimum and 0.770 inches maximum
-
Case Material
plastic
-
Center To Center Distance Between Terminals Parallel To Length
0.673 inches minimum and 0.735 inches maximum
-
Mounting Surface To Terminal End Distance
1.281 inches minimum and 1.343 inches maximum
-
Pole Quantity
1
-
Mounting Facility Type And Quantity
1 threaded bushing w/panel seal
-
Storage Type
general purpose warehouse
-
Thread Quantity Per Inch
32
-
Operating Voltage Type And Rating Per Pole In Volts
120.0 ac
-
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
2500.0 ac
-
Manual Actuator Type And Quantity
1 push-pull
-
Actuator Position Designation
at pole one
-
Internal Trip Release Configuration
series trip
-
Trip Delay Time In Seconds Per Rated Continuous Current
4.000 minimum at 200 pct and 20.000 maximum at 200 pct
-
Inclosure Protection Type For Which Designed
general purpose
-
Special Features
breaker terminal furnished with lockwasher and phillips head screw
-
Unpackaged Unit Weight
0.057 pounds
-
Proprietary Characteristics
pacs
-
Thread Series Designator
uns
-
Terminal Type And Quantity
2 tab w/screw