Technical Characteristics
-
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
300.0 ac and
-
Trip Release Method
magnetic single location
-
Trip Release Characteristic
time delay single location
-
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
150.0 single location
-
Actuator Position Designation
at pole one
-
Internal Trip Release Configuration
series trip single location
-
Nominal Thread Size
0.375 inches
-
Switch Location And Position Designation
internal at pole one
-
Trip Delay Time In Seconds Per Rated Continuous Current
0.500 minimum at 200 pct and
-
Inclosure Protection Type For Which Designed
hermetically sealed
-
Switch Terminal Type
tab, solder lug
-
Switch Current Rating And Type In Amps
0.5 ac and
-
Iii Unpackaged Unit Weight
50.0 grams
-
Non-Definitive Government Spec/Std Reference
mil-c-39019/2
-
Test Data Document
81349-mil-c-39019 specification
-
Terminal Type And Quantity
2 wire hook
-
Maximum Continuous Load Current Rating Per Pole
6.0 amperes dc single location
-
Operating Voltage Type And Rating Per Pole In Volts
240.0 ac and
-
Body Length
1.531 inches minimum and
-
Body Width
0.625 inches maximum
-
Case Material
metal
-
Switch Contact Arrangement
single pole, double throw
-
Iii Fragility Factor
moderately rugged
-
Mounting Surface To Terminal End Distance
1.669 inches minimum and
-
Mounting Facility Type And Quantity
1 threaded bushing w/panel seal
-
Iii Storage Type
general purpose warehouse
-
Features Provided
high inrush protection
-
Maximum Continuous Load Current Rating Per Pole
6.0 amperes ac and
-
Definitive Government Spec/Std Reference
m39019/02-323
-
Manufacturers Code
81349
-
Thread Series Designator
unef
-
Specification/Standard Data
81349-mil-c-39019/2 government specification
-
Body Style
2a single pole type
-
Bushing Length
0.332 inches minimum and
-
Bushing Length
0.380 inches maximum
-
Body Length
1.562 inches maximum
-
Body Width
0.594 inches minimum and
-
Center To Center Distance Between Terminals Parallel To Length
0.875 inches minimum and
-
Center To Center Distance Between Terminals Parallel To Length
0.906 inches maximum
-
Mounting Surface To Terminal End Distance
1.700 inches maximum
-
Pole Quantity
1
-
Thread Quantity Per Inch
32
-
Operating Voltage Type And Rating Per Pole In Volts
50.0 dc single location
-
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
500.0 dc single location
-
Circuit Protection Type
overcurrent single location
-
Reset Method
manual
-
Main Contact Tripping Mechanism Type
trip free
-
Manual Actuator Type And Quantity
1 toggle
-
Actuator Function
trip-reset
-
Auxiliary Switch Function And Quantity
1 alarm
-
Trip Delay Time In Seconds Per Rated Continuous Current
9.000 maximum at 200 pct single location
-
Switch Current Rating And Type In Amps
0.5 dc
-
Switch Voltage Rating And Type In Volts
120.0 ac and
-
Switch Voltage Rating And Type In Volts
50.0 dc
-
Frequency In Hertz
400.0 single location