Technical Characteristics

  • Maximum Continuous Load Current Rating Per Pole

    150.0 amperes ac all locations

  • Mounting Facility Type And Quantity

    4 threaded stud

  • Operating Voltage Type And Rating Per Pole In Volts

    600.0 ac all locations

  • Auxiliary Switch Function And Quantity

    1 control

  • Thread Series Designator

    uns

  • Case Material

    plastic

  • Nominal Thread Size

    0.938 inches

  • Circuit Protection Type

    overcurrent all locations

  • Reset Method

    manual

  • Body Length

    5.999 inches nominal

  • Center To Center Distance Between Terminals Parallel To Width

    1.500 inches nominal

  • Storage Type

    general purpose warehouse

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    1.484 inches nominal

  • Switch Current Rating And Type In Amps

    10.0 ac

  • Trip Release Characteristic

    time delay all locations

  • Actuator Function

    trip-reset

  • Manual Actuator Type And Quantity

    1 push button

  • Thread Quantity Per Inch

    32

  • Trip Release Method

    thermal-magnetic all locations

  • Trip Delay Time In Seconds Per Rated Continuous Current

    40.000 minimum at 200 pct all locations and 125.000 maximum at 200 pct all locations

  • Body Height

    3.000 inches nominal

  • Actuator Position Designation

    at pole two

  • Main Contact Tripping Mechanism Type

    nontrip free

  • Switch Contact Arrangement

    single pole, double throw

  • Switch Terminal Type

    bus bar

  • Center To Center Distance Between Terminals Parallel To Length

    5.124 inches nominal

  • Body Style

    multipole-single actuator type

  • Trip Release Ambient Temp Rating

    25.0 deg celsius nominal all locations

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    10000.0 ac all locations

  • Frequency In Hertz

    60.0 all locations

  • Switch Voltage Rating And Type In Volts

    120.0 ac

  • Switch Location And Position Designation

    external at pole two

  • Arc Quenching Method

    magnetic blowout

  • Terminal Type And Quantity

    3 threaded stud

  • Boss Height

    0.125 inches nominal

  • Inclosure Protection Type For Which Designed

    general purpose

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    6.000 inches nominal

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    200.0 all locations

  • Fragility Factor

    moderately rugged

  • Body Width

    4.468 inches nominal

  • Pole Quantity

    3

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...