NSN: 5925-01-236-6722

Technical Characteristics

  • Center To Center Distance Between Terminals Parallel To Length

    1.499 inches minimum and 1.561 inches maximum

  • Body Width

    2.265 inches maximum

  • Nonturn Device Length

    0.641 inches minimum and 0.671 inches maximum

  • Manual Actuator Type And Quantity

    1 toggle

  • Specification/Standard Data

    81349-mil-c-55629/22 government specification

  • Main Contact Tripping Mechanism Type

    trip free

  • Arc Quenching Method

    magnetic blowout

  • Mounting Surface To Terminal End Distance

    2.232 inches maximum

  • Frequency In Hertz

    400.0 all locations

  • Trip Delay Time In Seconds Per Rated Continuous Current

    2.100 minimum at 200 pct all locations and 20.000 maximum at 200 pct all locations

  • Body Length

    1.969 inches minimum and 2.031 inches maximum

  • Auxiliary Switch Function And Quantity

    1 alarm

  • Thread Series Designator

    un

  • Terminal Type And Quantity

    6 tab w/screw

  • Nonturn Device Location

    at 9 oclock and at 3 oclock and at 12 oclock

  • Bushing Length

    0.464 inches minimum and 0.526 inches maximum

  • Switch Location And Position Designation

    internal at pole one

  • Case Material

    plastic

  • Fragility Factor

    moderately rugged

  • Switch Terminal Type

    tab, solder lug

  • Special Handling Feature

    magnetic

  • Pole Quantity

    3

  • Circuit Protection Type

    overcurrent all locations

  • Center To Center Distance Between Terminals Parallel To Width

    0.735 inches minimum and 0.765 inches maximum

  • Reset Method

    manual

  • Nominal Thread Size

    0.500 inches

  • Mounting Facility Type And Quantity

    1 threaded bushing w/panel seal

  • Storage Type

    general purpose warehouse

  • Trip Release Characteristic

    time delay all locations

  • Actuator Function

    trip-reset

  • Internal Trip Release Configuration

    series trip all locations

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    1000.0 ac all locations

  • Nonturn Device Diameter

    0.138 inches nominal

  • Nonturn Device Width

    0.735 inches minimum and 0.765 inches maximum

  • Thread Quantity Per Inch

    32

  • Operating Voltage Type And Rating Per Pole In Volts

    240.0 ac all locations

  • Maximum Continuous Load Current Rating Per Pole

    7.5 amperes ac all locations

  • Trip Release Method

    magnetic all locations

  • Switch Current Rating And Type In Amps

    10.0 ac and 2.0 dc

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0 all locations

  • Actuator Position Designation

    at pole two

  • Inclosure Protection Type For Which Designed

    fungus resistant

  • Switch Contact Arrangement

    single pole, double throw

  • Switch Voltage Rating And Type In Volts

    250.0 ac and 50.0 dc

  • Body Style

    multipole-single actuator type

  • Test Data Document

    81349-mil-c-55629 specification (includes engineering type bulletins, brochures,etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general type

  • ~1

    data on certain environmental and performanc

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...