NSN: 5925-01-237-7937

Circuit Breakers

CIRCUIT BREAKER

5925 - Circuit Breakers

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Fragility Factor

    moderately rugged

  • Center To Center Distance Between Terminals Parallel To Width

    0.750 inches nominal

  • Trip Release Characteristic

    instantaneous all locations

  • Precious Material And Location

    plated contacts silver

  • Bushing Length

    0.250 inches nominal

  • Pole Quantity

    3

  • Circuit Protection Type

    overcurrent all locations

  • Thread Series Designator

    unc

  • Reset Method

    manual

  • Trip Release Ambient Temp Rating

    -65.0 deg celsius minimum all locations and 71.0 deg celsius maximum all locations

  • Precious Material

    silver

  • Storage Type

    general purpose warehouse

  • Actuator Function

    trip-reset

  • Manual Actuator Type And Quantity

    1 push button

  • Nonturn Device Location

    at 12 oclock

  • Thread Quantity Per Inch

    32

  • Trip Release Method

    thermal-magnetic all locations

  • Actuator Position Designation

    at pole two

  • Maximum Continuous Load Current Rating Per Pole

    3.0 amperes ac all locations

  • Body Style

    multipole-single actuator type

  • Nonturn Device Length

    0.045 inches nominal

  • Body Width

    1.300 inches maximum

  • Terminal Type And Quantity

    6 threaded stud

  • Center To Center Distance Between Terminals Parallel To Length

    1.375 inches nominal

  • Nominal Thread Size

    0.138 inches

  • Body Length

    2.063 inches maximum

  • Main Contact Tripping Mechanism Type

    trip free

  • Arc Quenching Method

    magnetic blowout

  • Unpackaged Unit Weight

    154.0 grams

  • Nonturn Device Radius

    0.375 inches nominal

  • Inclosure Protection Type For Which Designed

    general purpose

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    138.0 all locations

  • Mounting Facility Type And Quantity

    2 threaded bushing

  • Frequency In Hertz

    400.0 all locations

  • Nonturn Device Diameter

    0.093 inches nominal

  • Operating Voltage Type And Rating Per Pole In Volts

    120.0 ac all locations

  • Mounting Surface To Terminal End Distance

    1.875 inches maximum

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    300.0 ac all locations

  • Case Material

    plastic

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...